PERIODIC MAINTENANCE CHECKLIST
Visually check the entire Liftgate for excessively worn parts and broken welds, especially the
Hinge Pins. See PARTS BREAKDOWN section for replacement parts. Also, do the Semi-
annual and Quarterly Maintenance checks.
Annually
Quarterly
Semi-annually
Visually check the Platform Hinge Pins for excessive wear and broken welds. See PARTS
BREAKDOWN section for replacement parts. Also, do the Quarterly Maintenance checks.
Never operate the Liftgate with
parts loose or missing.
WARNING
!!
!!
!
+20 to +150 Degrees F - Grade ISO 32
Below + 20 Degrees F - Grade ISO 15
If Hydraulic Fluid appears contaminated, refer to the CHANGING HYDRAULIC FLUID
procedure on following page.
Check the Hydraulic Fluid level in the Pump Reservoir. If hydraulic fluid must be added, select
the correct grade of fluid to use at your location.
Keep track of the grade of Hydraulic Fluid in the Pump Reservoir and never mix two different
grades of fluid.
Check all Hoses and Fittings for chaffing and fluid leaks. Replace if necessary.
Check electrical wiring for chaffing and make sure wiring connections are tight and free of
corrosion.
Check that all WARNING and instruction decals are in place and legible.
Check that all roll pins are in place and protrude evenly from both sides of Hinge Pin collar.
Replace roll pins if necessary.