Chapter 6 Operation Guide
5-Start Step
WARNING
Make sure that all the electrical connections (including cooling water
connections) are connected prior to use. All the connectors must be held
steady with screws if possible.
NEVER look directly into the output fiber and make sure that you wear the
laser safety eyewear while operating the product.
Make sure all power is removed from the laser when wiring.
Starting procedures are as follows:
1
Start the Chiller;
2
Remove the end cap of the collimator;
3
Make sure that the end surface of the collimator is clean and not covered
with impurities;
4
Make sure that the emergency stop switch is turned on;
5
Open the power supply of the laser;
6
Place the key switch of the front panel on position "ON".
7
Press the START button on the front panel. (For external control method)
6- Mode Description
The working modes of the laser are as follows:
1
Internal control: Control the output of the laser via control software. This
mode is used for checking whether the laser is normal or not, and testing the
laser power.
2
External Control: Control the output of the laser via external control line
(EE, modulation, 0-10V analog voltage and START button). This mode is used
for cutting and welding.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MAXPhotonics MFSC-1000X G4.0 Series and is the answer not in the manual?

MAXPhotonics MFSC-1000X G4.0 Series Specifications

General IconGeneral
BrandMAXPhotonics
ModelMFSC-1000X G4.0 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals