When the unit is off, it can be activated with bypass output and can continue to charge the battery.
Maximum charging current up to 200A depending on model.
AC input range of 90-280V, ideal for generator applications.
Option to prioritize grid or battery power.
Control over battery charging profile, voltage, and low voltage points.
Intelligent adjustment of over-discharge, voltage, fan speed, and core temperature.
Comprehensive protection against over-charge, overload, short-circuit, and over-temperature.
Shows the wiring connections for battery, PV, AC input/output, and remote control.
Technical specifications for inverter operation in line mode.
Technical specifications for charging in utility mode.
Specs for solar and grid charging, including MPPT controller.
Describes the three-phase charging process: Boost CC, Boost CV, and Float.
Defines transitions between charging stages based on voltage and time.
Explains the function of Esc, Scroll, and Enter keys for operation and settings.
Describes the meaning of LCD backlight, Fault LED, Battery LED, and Utility/Inverter LED lights.
Icons and descriptions for input voltage, frequency, and battery voltage.
Icons indicating setting programs, warnings, and fault codes.
Icons for output voltage, frequency, load percent, and load in VA/Watt.
Icon showing battery level based on percentage.
Indicates when the alarm is disabled.
Option to exit the setting mode.
Configures the output frequency to 50Hz or 60Hz.
Sets AC input range for Appliance (APL) or UPS mode.
Selects battery type: AGM, Flooded, Li-ion, or Self-defined.
Sets the maximum charging current from utility.
Sets the voltage at which the inverter shuts off to protect the battery.
Enables switching to utility mode during overload in battery mode.
Enables or disables the inverter's buzzer alerts.
Controls the LCD backlight status (on or off after inactivity).
Defines the priority for supplying power: Utility, PV, or Battery.
Displays input and output voltages.
Displays the input frequency.
Displays the current battery voltage.
Displays the PV input voltage for MPPT charge controllers.
Displays the PV input power for MPPT charge controllers.
Displays the output frequency.
Displays the current charging current.
Displays the load in Volt-Amperes.
Displays the load in Watts.
Displays the load as a percentage of capacity.
Troubleshooting for overload condition.
Troubleshooting for high output voltage.
Troubleshooting for output short circuit.
Troubleshooting for high battery voltage.
Troubleshooting for over-temperature condition.
Troubleshooting for over current during charging.
Troubleshooting for inverter soft start timeout.
Troubleshooting for low output voltage.
Troubleshooting for abnormal current sensor.
Warning for overload condition with load percentage and working time.
Warning for low battery voltage, indicating charging is needed.
Warning for power derating due to low utility voltage.
Warning for disconnected TX NTC sensor.
Warning for disconnected INV NTC sensor.
Warning when utility electricity does not match the inverter.
Fault warning for over charging current in MPPT.
Fault warning for low battery voltage in MPPT.
Fault warning for high battery voltage in MPPT.
Fault warning for high temperature in MPPT.
Fault warning for over voltage from PV in MPPT.