EasyManua.ls Logo

MAXXCELL OG-5KMAX - User Manual

MAXXCELL OG-5KMAX
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USER GUIDE
Solar Inverter
Solar Inverter
358-010009-01
www.maxxcell.com.au
Question and Answer IconNeed help?

Do you have a question about the MAXXCELL OG-5KMAX and is the answer not in the manual?

Summary

Features

Bypass charging function

When the unit is off, it can be activated with bypass output and can continue to charge the battery.

High charging current

Maximum charging current up to 200A depending on model.

Wide range of AC input voltage

AC input range of 90-280V, ideal for generator applications.

Grid or battery priority option

Option to prioritize grid or battery power.

Battery Charging Program

Control over battery charging profile, voltage, and low voltage points.

Intelligent features

Intelligent adjustment of over-discharge, voltage, fan speed, and core temperature.

Safety features

Comprehensive protection against over-charge, overload, short-circuit, and over-temperature.

Diagram

Connection diagram

Shows the wiring connections for battery, PV, AC input/output, and remote control.

Specifications

Line Mode Specifications

Technical specifications for inverter operation in line mode.

Utility Charge Mode Specifications

Technical specifications for charging in utility mode.

Solar Charging & Grid Charging

Specs for solar and grid charging, including MPPT controller.

Charge Algorithm

Charging way

Describes the three-phase charging process: Boost CC, Boost CV, and Float.

Charge Stage Transition Definitions

Defines transitions between charging stages based on voltage and time.

Front Panel

Function Key

Explains the function of Esc, Scroll, and Enter keys for operation and settings.

Indicator light instruction

Describes the meaning of LCD backlight, Fault LED, Battery LED, and Utility/Inverter LED lights.

LCD Display Icons

Input Source Information

Icons and descriptions for input voltage, frequency, and battery voltage.

Configuration Program and Fault Information

Icons indicating setting programs, warnings, and fault codes.

Output Information

Icons for output voltage, frequency, load percent, and load in VA/Watt.

Battery Information

Icon showing battery level based on percentage.

Mode Operation Information

Mute Operation

Indicates when the alarm is disabled.

LCD Setting

Exit setting

Option to exit the setting mode.

Output frequency setting

Configures the output frequency to 50Hz or 60Hz.

Utility input range setting

Sets AC input range for Appliance (APL) or UPS mode.

Battery type setting

Selects battery type: AGM, Flooded, Li-ion, or Self-defined.

Max utility charging current setting

Sets the maximum charging current from utility.

LCD Setting

Low DC cut-off voltage

Sets the voltage at which the inverter shuts off to protect the battery.

Overload bypass function

Enables switching to utility mode during overload in battery mode.

Buzzer Alarm

Enables or disables the inverter's buzzer alerts.

Back light of LCD

Controls the LCD backlight status (on or off after inactivity).

Output source priority

Defines the priority for supplying power: Utility, PV, or Battery.

Display Information

Input voltage;Output voltage

Displays input and output voltages.

Input frequency

Displays the input frequency.

Battery voltage

Displays the current battery voltage.

PV voltage

Displays the PV input voltage for MPPT charge controllers.

PV power

Displays the PV input power for MPPT charge controllers.

Output frequency

Displays the output frequency.

Charging current

Displays the current charging current.

Load in VA

Displays the load in Volt-Amperes.

Load in Watt

Displays the load in Watts.

Load percentage

Displays the load as a percentage of capacity.

Fault Code Table

Overloaded happens

Troubleshooting for overload condition.

Output voltage high

Troubleshooting for high output voltage.

Output short

Troubleshooting for output short circuit.

Battery voltage high

Troubleshooting for high battery voltage.

Over temperature

Troubleshooting for over-temperature condition.

Over current happen in charging mode

Troubleshooting for over current during charging.

Inv soft start timeout

Troubleshooting for inverter soft start timeout.

Output voltage low

Troubleshooting for low output voltage.

Current sensor is abnormal

Troubleshooting for abnormal current sensor.

Warning Code Table

Overload

Warning for overload condition with load percentage and working time.

Battery low

Warning for low battery voltage, indicating charging is needed.

Power derating

Warning for power derating due to low utility voltage.

TX NTC is disconnected

Warning for disconnected TX NTC sensor.

INV NTC is disconnected

Warning for disconnected INV NTC sensor.

Flash

Warning when utility electricity does not match the inverter.

Faults for over charging current of built in MPPT

Fault warning for over charging current in MPPT.

Faults for battery low voltage of built in MPPT

Fault warning for low battery voltage in MPPT.

Faults for battery high voltage of built in MPPT

Fault warning for high battery voltage in MPPT.

Faults for high temperature of built in MPPT

Fault warning for high temperature in MPPT.

Faults for pv over voltage of built in MPPT

Fault warning for over voltage from PV in MPPT.

MAXXCELL OG-5KMAX Specifications

General IconGeneral
BrandMAXXCELL
ModelOG-5KMAX
CategoryInverter
LanguageEnglish