Troubleshooting:
problem
countermeasure
1
indicator light for power
supply not working
Check the connector or replace a new
one
Check your circuit breaker to confirm
power at the wall outlet
replace the circuit panel
2
Indicator light for function
is not working
Replace the relevant control panel
Replace the circuit board
check the connection of the
temperature sensor
3
Infrared Heater not
heating up
Replace heater panel
Check that the connections are sung
and tight
check the connection of the
temperature sensor
replace the circuit board
4
Odor from the sauna
Power supply may need to be
replaced
5
Light bulb is not working
Remove burned out light bulb and
replace it
Check connection and/or replace the
lamp assembly
Replace the relevant control panel
6
Sauna is not powering up
Plug the power cord into wall outlet
Check your circuit breaker to confirm
power at the wall outlet
Replace the power supply or related
circuit board
7
The temperature display
shows "EP"
Disconnect and reconnect the
connector of temperature sensor or
change to a new temperature sensor
8
The temperature display
shows "H"
Turn off the unit, and contact the
manufacturer
9
Speaker does not work
Replace with a new one of the same
specifications