C – 2 16023515 ©2005 Maytag Services
LP Conversion Instructions (Models CG11000AD*, CPL1110AD*,
YPL1110AD*)
Pressure Regulator Conversion
1. Remove range from installation position.
2. Turn off range gas supply.
3. Remove top grates and range top.
4. Remove gas line from pressure regulator.
5. Remove regulator converter cap and force plastic plunger from bottom of cap.
6. Turn plunger over and snap back into cap.
NOTE: Plunger must snap into position, and the type of gas being supplied (NAT or LP) must be visible on lower
side of plunger.
7. Insert converter cap back into regulator.
Pressure Regulator Conversion
Oven Pilot Conversion
1. Remove oven control knob.
2. Turn gas selector screw to N (Natural) or L (LP).
3. Reattach knob.
Natural LP
Oven Pilot Conversion
Type of Gas Top Burner Orifice Hoods Oven Orifice Hood
LP .0355 .0512
Natural #54 #46
Orifice Hood Table