INSTALLATION / PERFORMANCE CHECK LIST
ELECTRICAL SYSTEM:
Electrical connections tight? YES NO
Line voltage polarity correct? YES NO
Supply Voltage: ________________________________ VOLTS
Has the thermostat been calibrated? YES NO
Is the thermostat level? YES NO
Is the heat anticipator setting correct? YES NO
GAS SYSTEM:
Gas Type: (circle one)
Natural
Gas
Propane
Gas pipe connections leak tested? YES NO
Gas Line Pressure: ____________________________ (in - W.C.)
Installation Altitude: ______________________________ (FT.)
Deration Percentage: ______________________________ (%)
Furnace Input: _________________________________ (Btuh)
Supply Air Temperature: __________________________ (° F)
Return Air Temperature: __________________________ (° F)
Temperature Rise: _______________________________ (° F)
COMBUSTION AIR & VENTING SYSTEM:
Is there adequate fresh air supply for
combustion and ventilation?
YES NO
Vent free from restrictions? YES NO
Filter(s) secured in place? YES NO
Filter(s) clean? YES NO
Flue connections tight? YES NO
Is there proper draft? YES NO
INSTALLER NAME:
CITY: STATE:
INSTALLATION ADDRESS:
CITY: STATE:
UNIT MODEL #
UNIT SERIAL #
Minimum clearances per Table 1
(page 6)?
YES NO
Has the owner’s information been
reviewed with the home-owner?
YES NO
Has the literature package been
left near the furnace?
YES NO
ATTENTION INSTALLERS:
It is your responsibility to know this product better than your customer.
This includes being able to install the product according to strict
safety guidelines and instructing the customer on how to operate
and maintain the equipment for the life of the product. Safety should
always be the deciding factor when installing this product and us-
ing common sense plays an important role as well. Pay attention to
all safety warnings and any other special notes highlighted in the
manual. Improper installation of the furnace or failure to follow safety
warnings could result in serious injury, death, or property damage.
These instructions are primarily intended to assist qualifi ed individuals
experienced in the proper installation of this appliance. Some local
codes require licensed installation/service personnel for this type of
equipment. Please read all instructions carefully before starting the
installation. Return these instructions to the customer’s package for
future reference.
PROPOSITION 65 WARNING: This product
contains chemicals known to the state of
California to cause cancer, birth defects or
other reproductive harm.
WARNING:

Table of Contents

Related product manuals