EasyManua.ls Logo

Mazda RX-8 2009 - Full-Auto Air Conditioner Function [Full-Auto Air Conditioner]; Control List; Control Transition Based on Switch Operation

Mazda RX-8 2009
299 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONTROL SYSTEM [FULL-AUTO AIR CONDITIONER]
07-40–7
07-40
FULL-AUTO AIR CONDITIONER FUNCTION [FULL-AUTO AIR CONDITIONER]
id0740a1100600
Control List
x Function is based on five basic control items and two supplementary function items.
Control Transition Based on Switch Operation
Airflow temperature control, airflow volume control
*1
: Warm-up correction prioritized
*2
: Increases airflow to a level closer to current condition
*3
: Decreases airflow to a level closer to current condition
Basic control Control content Correction control
Airflow temperature control Airflow temperature automatic control x Air mix actuator opening angle correction
x MAX HOT and MAX COLD correction
Airflow volume control Airflow volume automatic control x Mild start correction
x Warm-up correction
x MAX HOT and MAX COLD correction
x Defroster correction
x Ambient temperature
x Burn prevention function at start
Airflow volume manual control x Defroster correction
x Burn prevention at start function
Airflow mode control Airflow mode automatic control x Warm-up correction
x MAX HOT and MAX COLD correction
Airflow mode manual control
Air intake control Air intake automatic control x Defroster correction
x MAX HOT and MAX COLD correction
Air intake manual control x Defroster correction
A/C compressor control A/C compressor automatic control x Defroster correction
x Ambient correction (during FRESH mode)
x MAX HOT and MAX COLD correction
A/C compressor manual control x Defroster correction
Supplemental functions
Fail-safe function
On-board function
Operation switch
Airflow temperature
control
Airflow volume control
Control prior to
switch operation
Control prior to switch operation
Automatic control Automatic control
Automatic control
(Defroster
correction)
Manual control
Fan switch
UP Automatic control
Manual control
*2
Manual control
*2
Manual control
DOWN Automatic control
Manual control
*3
Manual control
*3
Manual control
Airflow mode selector switch Automatic control Automatic control
Condition prior to
operation
No change
Defroster Automatic control Defroster correction
Condition prior to
operation
Automatic control
(Defroster correction)
A/C switch Automatic control Automatic control No change No change
REC/FRESH switch Automatic control Automatic control No change No change
Temperatu
re control
dial
18 (left end) MAX COLD HI HI No change
19—31 Automatic control Automatic control No change No change
32 (right end) MAX HOT
AUTO HI
*1
AUTO HI No change

Table of Contents