30125-48 Rev. 1.0 | 05AUG2021
Page 8
Device-Specic Commands
Command #130: Reset Totalizer
This command allows the user to reset a specic totalizer. It takes eect only if the selected totalizer is enable to be reset.
Refer to ProComm IOM Manual for the converter function code and MCP command.
Byte Format Description
Request Data Bytes 0 Enum Totalizer ID to reset
Response Data Bytes 0 Enum Totalizer ID reset
Command-Specic
Response Codes
0 Success No command-specic errors
1 Undened
2 Error Invalid selection
3 - 4 Undened
5 Error Too few data bytes received
7 Error Device In write protect mode
Command #131: Read Tube Diameter
This command returns the tube diameter in a xed unit (mm).
Byte Format Description
Request Data Bytes 0
Response Data Bytes
0 Enum Unit code (xed)
1 - 4 Float Tube diameter
Command-Specic
Response Codes
0 Success No command-specic errors
Command #132: Read Coil Frequency
This command returns the coil frequency in a xed unit (Hz).
Byte Format Description
Request Data Bytes 0
Response Data Bytes
0 Enum Unit code (xed)
1 - 4 Float Coil frequency
Command-Specic
Response Codes
0 Success No command-specic errors
Command #133: Read Low Flow Cut-O
This command returns the low ow cut-o setting in xed unit (%).
Byte Format Description
Request Data Bytes 0
Response Data Bytes
0 Enum Unit code (xed)
1 - 4 Float Coil frequency
Command-Specic
Response Codes
0 Success No command-specic errors