30125-48 Rev. 1.0 | 05AUG2021
Page 8
Device-Specic Commands
Command #130: Reset Totalizer
This command allows the user to reset a specic totalizer. It takes eect only if the selected totalizer is enable to be reset.
Refer to ProComm IOM Manual for the converter function code and MCP command.
Byte Format Description
Request Data Bytes 0 Enum Totalizer ID to reset
Response Data Bytes 0 Enum Totalizer ID reset
Command-Specic
Response Codes
0 Success No command-specic errors
1 Undened
2 Error Invalid selection
3 - 4 Undened
5 Error Too few data bytes received
7 Error Device In write protect mode
Command #131: Read Tube Diameter
This command returns the tube diameter in a xed unit (mm).
Byte Format Description
Request Data Bytes 0
Response Data Bytes
0 Enum Unit code (xed)
1 - 4 Float Tube diameter
Command-Specic
Response Codes
0 Success No command-specic errors
Command #132: Read Coil Frequency
This command returns the coil frequency in a xed unit (Hz).
Byte Format Description
Request Data Bytes 0
Response Data Bytes
0 Enum Unit code (xed)
1 - 4 Float Coil frequency
Command-Specic
Response Codes
0 Success No command-specic errors
Command #133: Read Low Flow Cut-O
This command returns the low ow cut-o setting in xed unit (%).
Byte Format Description
Request Data Bytes 0
Response Data Bytes
0 Enum Unit code (xed)
1 - 4 Float Coil frequency
Command-Specic
Response Codes
0 Success No command-specic errors