EasyManua.ls Logo

McCrometer ProComm - Tables; Write Protect; Totalizers

McCrometer ProComm
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30125-48 Rev. 1.0 | 05AUG2021
Page 9
Tables
Command #134: Read Density
This command returns the uid density setting in xed unit (Kg/l).
Byte Format Description
Request Data Bytes 0
Response Data Bytes
0 Enum Unit code (xed)
1 - 4 Float Density
Command-Specic
Response Codes
0 Success No command-specic errors
Command #135: Read Flow Direction
This command returns the ow direction.
Byte Format Description
Request Data Bytes 0
Response Data Bytes 0 Enum Flow direction
Command-Specic
Response Codes
0 Success No command-specic errors
Command #136: Read Mass Unit Enable
This command returns the mass unit enable setting.
Byte Format Description
Request Data Bytes 0
Response Data Bytes 0 Enum Mass unit enable
Command-Specic
Response Codes
0 Success No command-specic errors
10.0 Tables
10.1 Write Protect
Value Description
0 Not Write Protected
1 Write Protected
10.2 Totalizers
Value Description
0 Totalizer Positive (Flow Rate Positive)
1 Totalizer Negative (Flow Rate Negative)
2 Partial Totalizer Positive (Flow Rate Positive)
3 Partial Totalizer Negative (Flow Rate Negative)

Other manuals for McCrometer ProComm