If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF
Then, pull on the ring on the Safety Valve to quickly release stored air pressure�
G,)+:1)'9*F3,)*+77*FV()/:
1� If the Compressor automatically shuts off
before reaching its normal cutoff pressure:
a� Shut off all tools�
b� Turn Power Switch OFF
c� Unplug Compressor
d� Wait until the Compressor cools down
(about 10 minutes);
e� Plug in Compressor
f� Turn Power Switch ON�
g� Resume operation�
2� Possible causes of repeated automatic
shut off of the compressor are:
a� Using an extension cord that
is too long or narrow;
b� An air leak or open hose causing the compressor
to cycle too often and build up heat�
c� Turning Air Compressor off and
on again too quickly
3� Correct any issues before further use to
avoid damage to the compressor