EasyManua.ls Logo

McQuay MAC 100 CR - R407 C Cooling Performance; R407 C Cooling Only Performance Data

McQuay MAC 100 CR
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heat Pump - Cooling Only
Refrigerant: R 407C
MODEL
COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP.
CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
5 21.2 4.7 20.8 6.5 20.6 7.1 20.5 7.4 19.4 7.8 18.1 8.3 16.8 8.9
6 21.9 5.1 21.5 7.0 21.3 7.6 21.2 7.9 20.1 8.3 18.9 8.8 17.4 9.4
M4AC080CR
7 22.3 5.3 22.0 7.4 21.8 8.0 21.7 8.3 20.6 8.7 19.2 9.3 18.0 10.0
8 22.7 5.7 22.4 7.8 22.2 8.4 22.1 8.7 20.9 9.1 19.5 9.7 18.3 10.3
9 23.2 6.2 22.9 8.4 22.7 9.1 22.6 9.3 21.5 9.8 20.1 10.3 18.5 11.0
10 23.8 6.6 23.6 9.1 23.5 9.7 23.4 10.4 22.1 10.4 20.8 11.0 19.1 11.6
5 25.9 5.4 25.0 7.7 24.7 8.4 24.4 8.8 23.1 9.3 21.5 9.9 20.0 10.5
6 26.1 5.8 25.6 8.3 25.4 9.0 25.2 9.4 23.9 9.8 22.4 10.5 20.9 11.1
M4AC100CR
7 27.3 6.0 26.5 8.7 26.1 9.5 25.8 9.8 24.5 10.3 22.8 11.0 21.3 11.7
8 27.8 6.4 26.9 9.2 26.6 9.9 26.3 10.3 24.9 10.8 23.2 11.5 21.6 12.1
9 28.4 7.0 27.5 9.9 27.2 10.7 26.9 11.1 25.5 11.6 23.9 12.2 22.3 13.0
10 29.2 7.5 28.4 10.7 28.1 11.5 27.8 12.3 26.3 12.4 24.8 13.0 23.0 13.8
5 33.2 6.3 31.7 8.6 31.0 9.4 30.5 9.8 28.9 10.4 26.9 11.1 24.5 12.0
6 33.9 6.8 32.6 9.3 32.0 10.1 31.5 10.5 29.9 11.0 28.1 11.8 25.5 12.7
M4AC120CR
7 34.7 7.2 33.3 9.8 32.7 10.6 32.2 11.0 30.6 11.6 28.5 12.4 25.9 13.4
8 35.1 7.6 33.8 10.3 33.3 11.2 32.9 11.6 31.1 12.1 29.0 12.9 26.1 13.8
9 35.9 8.1 34.6 11.2 34.0 12.0 33.6 12.4 31.9 13.0 29.9 13.7 26.9 14.8
10 37.2 8.8 35.8 12.0 35.2 12.9 34.8 13.8 32.9 13.9 31.0 14.6 27.9 15.7
5 39.0 7.6 37.6 9.7 37.0 10.6 36.6 11.1 34.6 11.7 32.3 12.5 31.3 13.7
6 40.4 8.2 39.0 10.5 38.3 11.4 37.8 11.9 35.9 12.5 33.7 13.3 32.3 14.5
M4AC150CR
7 41.0 8.6 39.7 11.0 39.1 12.0 38.7 12.5 36.7 13.1 34.2 14.0 33.3 15.3
8 42.1 9.1 40.6 11.7 39.9 12.6 39.4 13.1 37.3 13.7 34.8 14.5 33.4 15.9
9 43.0 9.8 41.5 12.6 40.8 13.6 40.3 14.0 38.3 14.7 35.9 15.5 34.5 16.8
10 44.5 10.6 42.9 13.6 42.2 14.6 41.7 15.6 39.5 15.7 37.1 16.5 35.7 17.9
LEAVING WATER TEMP (°C)
28 32 35
AMBIENT TEMPERATURE (°C)
4219 4640
44
CH8-30 PUMP (120 & 150)
CH4-40 PUMP (080 & 100)

Other manuals for McQuay MAC 100 CR

Related product manuals