MAC-C-2004
Air-Cooled Mini Chiller
Models: MAC 080 C/CR
MAC 100 C/CR
MAC 120 C/CR
MAC 150 C/CR
M4AC 080 C/CR
M4AC 100 C/CR
M4AC 120 C/CR
M4AC 150 C/CR

Other manuals for McQuay MAC 100 CR

Questions and Answers

  • J
    Jennifer AdkinsAug 17, 2025
    What to do if McQuay Chiller compressor does not start?
    • A
      Ariana HahnAug 17, 2025
      If the McQuay Chiller compressor doesn't start, several factors could be at play. First, check the power supply to ensure it's active. Also, inspect the fuses and circuit breakers; replace any blown fuses and reset breakers after fixing the underlying fault. A tripped safety mechanism could also halt the unit; identify the type of safety shutdown, correct the issue, and then restart. Loose wiring is another potential cause; check wire connections and tighten any loose terminal screws. If none of these resolves the issue, the compressor itself may be faulty, and you should contact your local dealer.
  • J
    Joy TrujilloAug 20, 2025
    Why is my McQuay Chiller not cooling enough?
    • V
      Vanessa GarnerAug 20, 2025
      If your McQuay Chiller isn't providing sufficient cooling, several factors could be responsible. Begin by checking the thermostat setting and reset it to a cooler temperature if it's set too high. Other potential causes, such as a dirty condenser coil, insufficient refrigerant, improper water flow rate, or contaminated water in the system, require contacting your local dealer. Also, make sure that there is no obstacle blocking air inlet or outlet of the unit, and remove it if there is any.
  • A
    alexandraserranoAug 23, 2025
    What to do if the compressor does not start in McQuay MAC 100 CR Chiller?
    • T
      tracycurtisAug 23, 2025
      If the compressor on your McQuay Chiller isn't starting, begin by checking the power supply to ensure it's properly connected. Also, inspect the fuses and circuit breakers; replace any blown fuses and reset breakers after fixing the underlying fault. Other potential issues include defective contactors or coils, which may need repair or replacement, tripped safety devices (determine the cause and correct it before restarting), or loose wiring (check and tighten all connections). If none of these steps resolve the issue, the compressor itself may be faulty, and you should contact a local dealer.
  • N
    Nicole BenjaminAug 26, 2025
    How to fix a fan that does not work on McQuay MAC 100 CR Chiller?
    • K
      Kevin MaddoxAug 26, 2025
      If the fan on your McQuay Chiller isn't working, start by checking the power supply to ensure it's properly connected. If the power supply is fine, the fan motor may be faulty, in which case you should contact a local dealer.
  • C
    cfernandezAug 28, 2025
    What to do if McQuay MAC 100 CR shows reverse phase?
    • A
      Anne PetersonAug 28, 2025
      If the McQuay Chiller displays a reverse phase error, switch off the unit immediately and check the 3-phase wiring to ensure it's correctly configured.
  • J
    joshua22Aug 31, 2025
    What to do if R phase is missing in McQuay MAC 100 CR?
    • S
      Samuel JuarezAug 31, 2025
      If the McQuay Chiller indicates a missing R phase, switch off the unit and inspect the 3-phase wiring to ensure everything is properly connected.
  • T
    tbullockSep 2, 2025
    What to do if S phase is missing in McQuay MAC 100 CR Chiller?
    • B
      Brittany PettySep 3, 2025
      If the McQuay Chiller indicates a missing S phase, switch off the unit and inspect the 3-phase wiring to ensure everything is properly connected.
  • T
    Troy McintyreSep 5, 2025
    What to do if T phase is missing in McQuay MAC 100 CR?
    • C
      chad88Sep 6, 2025
      If the McQuay Chiller indicates a missing T phase, switch off the unit and inspect the 3-phase wiring to ensure everything is properly connected.
  • G
    gregoryalexanderSep 8, 2025
    What to do if S & T phases are missing in McQuay Chiller?
    • H
      helenloveSep 8, 2025
      If the McQuay Chiller indicates missing S & T phases, switch off the unit and inspect the 3-phase wiring to ensure everything is properly connected.
  • J
    Jessica HarrisSep 12, 2025
    Why McQuay MAC 100 CR shows Overload+?
    • M
      morrisjenniferSep 12, 2025
      If the McQuay Chiller is showing an overload error, it may be due to a high discharge temperature. In this case, you should check the refrigerant system.

Summary

Nomenclature and General Features

General Features and Specifications

Details unit design, refrigerant circuit, compressors, fans, evaporator, and safety features.

Unit Details and Protections

Chiller Panel Controller Overview

Chiller Panel Controller Hardware

Hardware Description & Key Explanations

Describes controller hardware views, legends, and key functions.

Chiller Panel Controller Installation

Installation & Chiller Network

Covers chiller network setup, wiring, and unit addressing for panel communication.

Chiller Panel Controller Configuration

Chiller Panel Controller Software

Software Description & Introduction

Introduces software capabilities for controlling and displaying chiller status.

Chiller Panel Controller Menus

Menu Structure Overview

Presents a diagram of the chiller panel's menu structure for navigation.

Chiller Menu Navigation

Chiller Menu Structures & Summary Pages

Outlines chiller menus and describes the four summary pages showing key status.

Chiller Panel Operations

Main Menu & Operation Menu

Details the main menu and how to use the operation menu for settings.

Chiller Panel Settings

Settings Menu & Set Parameter

Outlines advanced settings menu and 7 groups of parameters.

Chiller Panel Customization

Chiller Panel Timing

Chiller Scheduling and Alarms

Chiller Monitoring Features

Chiller Sensor Data

Operation User Manual

Starting & Panel ID Setup

Explains setting panel as Master/Slave and controlling chillers via Panel ID.

Chiller Operation Control

Chiller Operation Control & Startup

Covers initial startup, information gathering, and changing display units.

Chiller Power Control

Switching Unit ON;OFF

Details the various methods for switching the chiller ON or OFF.

Chiller Mode Selection

Switching Operation Mode

Explains how to switch between Cooling, Heating, and Boiling modes.

Chiller Temperature Settings

Changing Mode Set Temperature

Describes how to adjust cooling and heating setpoint temperatures.

Chiller Defrost Operations

Chiller Advanced Parameters

Advanced Parameter Settings

Introduces advanced parameter settings divided into 7 groups.

Chiller Security Settings

Chiller Time and Date

Chiller Programmable Schedule

Chiller Alarm Management

Viewing and Erasing Alarm Records

Covers viewing active and historical alarms and erasing records.

Chiller Sensor Monitoring

Chiller Operational Data

Chiller Panel Settings and Reset

Troubleshooting and Diagnostics

Problems and Troubleshooting

Table of common symptoms, causes, and troubleshooting steps.

Technical Appendix

Parameter Details

Operational Parameter Settings

Specifications Overview

Air Cooled Chiller - R22 Cooling Only

Provides detailed specifications for R22 cooling-only models.

R22 Heat Pump Specifications

Air Cooled Chiller - R22 Heat Pump

Details specifications for R22 heat pump models.

R407 C Cooling Specifications

R407 C Heat Pump Specifications

Performance Data

Heat Pump Cooling Performance

Heat Pump Heating Performance

R407 C Cooling Performance

R407 C Heat Pump Performance

Technical Data Tables

Glycol Correction Factors

Wiring Diagrams

Chiller Wiring Details

Chiller Electrical Connections

Chiller Electrical Schematics

Chiller Wiring Configurations

Special Precautions for R407 C

R407 C Handling

Installation Procedures

Installation Safety Precautions

Lists safety precautions to follow before installing the unit.

Installation Guidelines

Electrical Installation

Electrical and Wiring Guidelines

Provides wiring diagrams and cable size recommendations.

System Safety and Setup

Electrical & Water Piping Safety

General warnings on electrical safety, water piping setup, and refrigerant.

Servicing and Maintenance

Troubleshooting Guide

Common Problems and Solutions

Table of common symptoms, causes, and troubleshooting steps.

Schematic Diagrams

McQuay MAC 100 CR Specifications

General IconGeneral
ModelMAC 100 CR
Power Supply460V/3Ph/60Hz
CategoryChiller
Cooling Capacity100 tons
Compressor TypeScroll