EasyManua.ls Logo

McQuay MAC 150 C

McQuay MAC 150 C
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heat Pump – Cooling Mode
Refrigerant: R22
MODEL
COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP.
CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
5 22.1 4.5 21.6 6.0 21.5 6.6 21.3 7.1 19.7 7.7 19.1 7.9 17.8 8.4
6 22.8 4.9 22.4 6.4 22.2 7.1 22.1 7.6 20.4 8.1 19.7 8.4 18.4 8.8
MAC080CR
7 23.2 5.1 22.8 6.7 22.7 7.4 22.6 8.0 21.0 8.6 20.3 8.9 19.0 9.4
8 23.6 5.4 23.3 7.1 23.1 7.8 23.0 8.4 21.3 9.0 20.7 9.2 19.4 9.7
9 24.2 5.9 23.8 7.6 23.6 8.4 23.5 9.0 21.7 9.6 21.0 9.9 19.6 10.4
10 24.8 6.3 24.5 8.4 24.4 9.3 24.3 10.0 22.4 10.4 21.7 10.6 20.2 11.0
5 27.5 5.3 26.7 6.9 26.3 7.7 26.0 8.2 23.8 9.1 22.9 9.4 21.1 10.1
6 27.7 5.7 27.3 7.4 27.1 8.2 26.9 8.8 24.7 9.7 23.8 10.0 22.0 10.7
MAC100CR
7 29.0 5.9 28.2 7.8 27.8 8.6 27.5 9.2 25.2 10.2 24.2 10.5 22.4 11.3
8 29.6 6.3 28.7 8.2 28.3 9.1 28.1 9.7 25.6 10.6 24.7 11.0 22.7 11.7
9 30.2 6.8 29.3 8.8 29.0 9.7 28.7 10.4 26.3 11.3 25.3 11.7 23.4 12.5
10 31.0 7.4 30.3 9.7 29.9 10.8 29.7 11.5 27.2 12.3 26.2 12.6 24.2 13.3
5 33.7 6.2 32.4 7.8 31.8 8.5 31.3 9.1 28.6 9.8 27.5 10.1 25.4 10.7
6 34.4 6.6 33.3 8.3 32.8 9.1 32.4 9.7 29.7 10.4 28.6 10.7 26.4 11.3
MAC120CR
7 35.2 7.0 34.0 8.8 33.5 9.6 33.2 10.2 30.3 11.0 29.1 11.3 26.8 11.9
8 35.6 7.4 34.6 9.3 34.1 10.1 33.8 10.7 30.7 11.4 29.5 11.7 27.0 12.3
9 36.4 8.0 35.4 9.9 34.9 10.8 34.5 11.5 31.5 12.2 30.3 12.5 27.9 13.2
10 37.7 8.6 36.6 10.9 36.1 12.0 35.7 12.7 32.6 13.3 31.3 13.5 28.8 14.0
5 39.6 6.9 38.8 8.8 38.5 9.6 38.2 10.3 35.5 11.1 34.4 11.5 32.2 12.1
6 41.0 7.4 40.2 9.4 39.8 10.3 39.5 11.0 36.7 11.8 35.5 12.2 33.3 12.9
MAC150CR
7 41.6 7.9 40.9 9.9 40.7 10.8 40.4 11.5 37.6 12.5 36.5 12.9 34.3 13.6
8 42.7 8.3 41.9 10.4 41.5 11.4 41.2 12.1 38.1 13.0 36.9 13.4 34.4 14.1
9 43.6 9.0 42.8 11.2 42.4 12.2 42.1 13.0 39.1 13.9 37.9 14.2 35.5 15.0
10 45.2 9.7 44.3 12.3 43.9 13.5 43.6 14.4 40.5 15.1 39.2 15.4 36.7 15.9
LEAVING WATER TEMP (°C)
28 32 35
AMBIENT TEMPERATURE (°C)
4219 4640
41
CH8-30 PUMP (120 & 150)
CH4-40 PUMP (080 & 100)

Other manuals for McQuay MAC 150 C

Related product manuals