Heat Pump - Cooling Only
Refrigerant: R 407C
MODEL
COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP. COOL COMP.
CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT CAP. INPUT
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
5 21.2 4.7 20.8 6.5 20.6 7.1 20.5 7.4 19.4 7.8 18.1 8.3 16.8 8.9
6 21.9 5.1 21.5 7.0 21.3 7.6 21.2 7.9 20.1 8.3 18.9 8.8 17.4 9.4
M4AC080CR
7 22.3 5.3 22.0 7.4 21.8 8.0 21.7 8.3 20.6 8.7 19.2 9.3 18.0 10.0
8 22.7 5.7 22.4 7.8 22.2 8.4 22.1 8.7 20.9 9.1 19.5 9.7 18.3 10.3
9 23.2 6.2 22.9 8.4 22.7 9.1 22.6 9.3 21.5 9.8 20.1 10.3 18.5 11.0
10 23.8 6.6 23.6 9.1 23.5 9.7 23.4 10.4 22.1 10.4 20.8 11.0 19.1 11.6
5 25.9 5.4 25.0 7.7 24.7 8.4 24.4 8.8 23.1 9.3 21.5 9.9 20.0 10.5
6 26.1 5.8 25.6 8.3 25.4 9.0 25.2 9.4 23.9 9.8 22.4 10.5 20.9 11.1
M4AC100CR
7 27.3 6.0 26.5 8.7 26.1 9.5 25.8 9.8 24.5 10.3 22.8 11.0 21.3 11.7
8 27.8 6.4 26.9 9.2 26.6 9.9 26.3 10.3 24.9 10.8 23.2 11.5 21.6 12.1
9 28.4 7.0 27.5 9.9 27.2 10.7 26.9 11.1 25.5 11.6 23.9 12.2 22.3 13.0
10 29.2 7.5 28.4 10.7 28.1 11.5 27.8 12.3 26.3 12.4 24.8 13.0 23.0 13.8
5 33.2 6.3 31.7 8.6 31.0 9.4 30.5 9.8 28.9 10.4 26.9 11.1 24.5 12.0
6 33.9 6.8 32.6 9.3 32.0 10.1 31.5 10.5 29.9 11.0 28.1 11.8 25.5 12.7
M4AC120CR
7 34.7 7.2 33.3 9.8 32.7 10.6 32.2 11.0 30.6 11.6 28.5 12.4 25.9 13.4
8 35.1 7.6 33.8 10.3 33.3 11.2 32.9 11.6 31.1 12.1 29.0 12.9 26.1 13.8
9 35.9 8.1 34.6 11.2 34.0 12.0 33.6 12.4 31.9 13.0 29.9 13.7 26.9 14.8
10 37.2 8.8 35.8 12.0 35.2 12.9 34.8 13.8 32.9 13.9 31.0 14.6 27.9 15.7
5 39.0 7.6 37.6 9.7 37.0 10.6 36.6 11.1 34.6 11.7 32.3 12.5 31.3 13.7
6 40.4 8.2 39.0 10.5 38.3 11.4 37.8 11.9 35.9 12.5 33.7 13.3 32.3 14.5
M4AC150CR
7 41.0 8.6 39.7 11.0 39.1 12.0 38.7 12.5 36.7 13.1 34.2 14.0 33.3 15.3
8 42.1 9.1 40.6 11.7 39.9 12.6 39.4 13.1 37.3 13.7 34.8 14.5 33.4 15.9
9 43.0 9.8 41.5 12.6 40.8 13.6 40.3 14.0 38.3 14.7 35.9 15.5 34.5 16.8
10 44.5 10.6 42.9 13.6 42.2 14.6 41.7 15.6 39.5 15.7 37.1 16.5 35.7 17.9
LEAVING WATER TEMP (°C)
28 32 35
AMBIENT TEMPERATURE (°C)
4219 4640