Once the desired Max display mode has been selected, it is
possible to lock the mode, so that further pressing the MAX
key results in no change.
To access the MAX LOCK function, press and hold the
MENU key until page 1 of the main-menu appears.
Press and release the MENU key twice to access the main
menu page 3. Using the UP and DOWN keys, move the
arrow cursor to MAX LOCK, and press ENTER.
The display shows MAX LOCK:
OFF Unlocks the max display mode.
ON Locks the current max display mode.
Use the UP and DOWN keys to move the arrow cursor
against the desired selection and press ENTER.
The display will return to the main menu page 3, press the
ESC key to return to the main display.
Once the desired unit of measurement has been selected, it
is possible to lock the units, so that further pressing the
UNITS key results in no change.
To access the UNITS LOCK function, press and hold the
MENU key until page 1 of the main-menu appears.
Press and release the MENU key twice to access the main
menu page 3. Using the UP and DOWN keys, move the
arrow cursor to UNITS LOCK, and press ENTER.
The display shows UNITS LOCK:
OFF Unlocks the units.
ON Locks the units to the current setting.
Use the UP and DOWN keys to move the arrow cursor
against the desired selection and press ENTER.
The display will return to the main menu page 3, press the
ESC key to return to the main display.
MAX LOCK
MAX LOCK sub-menu 1
UNITS LOCK
UNITS LOCK sub-menu 1
Note: The UNITS/MENU key can
still be used to enter the menu
pages when the UNITS LOCK
function is enabled.