EasyManua.ls Logo

MECNOSUD SP80 - 5.3 Possible Failure and;or Anomalies

MECNOSUD SP80
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
7. Unscrew the screws Pos.3 and remove the piece Pos.4 (look at Pict. 5.7)
8. Unscrew the screws Pos.78 (look at Pict. 5.7) than remove the element (look at Pict. 5.8) composed of
pieces Pos. 10, Pos. 11, Pos. 12, Pos. 13
9. Remove the piece Pos. 11 (look at Pict. 5.8) and replace the bearings.
5.3 POSSIBLE FAILURE AND/OR ANOMALIES
ANOMALY
POSSIBLE CAUSE
POSSIBLE REMEDY
By pressing the key
start, the machine
does not start
Mancanza di energia
elettrica nella rete
Verificare il contatore generale, la presa, la spina
e il cavo di alimentazione
Emergency button
pressed
Re-set the emergency button in turning
it in clockwise direction.
Bowl cover lifted up
Close the cover bowl
Main power switch on
position “ O “
Turn the main O- I switch to position “ I ”.
Start button defective
Check and, if needed, replace the
defective parts.
During mixture cycle
phase spiral and/ or
bowl
slow down
The transmission belts
concerned are
loosen
Adjust the belt tension
The rotation direction
of the bowl is not
correct
The phases are inverted
Reverse on the plug the position of two phases