ALARM FUNCTIONS
DOORS, BONNET AD BOOT OPENING:
ADDITIONAL MODULES
IGNITION KEY
ON
OFF ON
ULTRASONIC SENSOR:
ABSORPTION SENSOR
WARNING:
ANTI-TAMPERING
When the system is activated the alarm is given/signalised by the siren, the direction indicators,
the LED and the additional warning horns. Cycles of about 25 seconds, with cut off by the
remote control or the emergency procedure.
2 different inputs are available:
- Instantaneous on the system activation.
- Delayedby30or50secondsonactivation,theninstantaneous.
The alarm cycle is not repeated if the door remains opened.
The alarm is repeated only if the door is closed and opened again after the current cycle is
terminated.
Unlimited alarm cycles.
:
The alarm cycle is repeated only if the alarm cause occurs again after the current cycle is
terminated. 1 alarm cycle - standard setting ; 3 alarm cycles - optional
As long as the system is activated a maximum of 10 alarm cycles is possible.
On the activation the input is delayed by 30 or 50 seconds, as chosen.
(for at least 2 seconds):
The starting attempt causes an alarm cycle.
The alarm is not repeated if the key is in the position (instrument panel lit).
The alarm is repeated only if the key is turned back in the position and then let in the
position for at least 2 secondsi.
Unlimited alarm cycles.
The alarm cycle is repeated with a break of 5 seconds, if the alarm cause persists
continuously.
The blinding/masking of the sensors, if detected on the system activation, causes some
warning signalings (LED, direction indicators, siren), followed by an alarm cycle. If detected
when the system is already activated, it causes 10 alarm cycles only in consequence of
another type of alarm.
As long as the system is activated a maximum of 10 alarm cycles is possible from the
ULTRASONIC sensor.
:
The alarm cycle is repeated only in case of a new absorption change.
As long as the system is activated a maximum of 10 alarm cycles is possible.
When activated it has a 50 / 60 second delay to allow the absorptions “stabilization”.
- If an alarm occurs during another one, this last one will be not considered.
- When the system is desactivated, if the automatic engine lock starts with a 5 minute delay,
from the second starting attempt (ignition key turned on for at least 2 seconds), an alarm
cycle i launched.
The internal microprocessor monitors the vehicle continuously, constantly adapting its working
parameters to the environment where it is installed to better understand and identify the real
alarms from false signalings.
The (anti-masking and anti-blinding) function constantly controls the
efficiency of the sensors and of their wirings, warning in case of any attempts. On its activation it
checks its correct working conditions and its own parameters in full, then it start the vehicle
surveillance (flashing LED).
The anomalies, if any, are signalised by the siren and by the direction indicators flashing for
some seconds, followed by an alarm cycle and by 5 BEEPS subsequent to the desactivation of
the system.
!
!
!
!
!
!
!
!
!
!
!
!
!
!
ULTRASONIC SENSOR
1 alarm cycle - standard setting ; 3 alarm cycles - optional.
.
21