30
DELAYED INPUTS ON THE SYSTEM ACTIVATION
DOORS BUTTONS REFERRED TO POSITIVE OR NEGATIVE
ADDITIONAL MODULES - PRE-ALARM FOR DUAL ZONE MODULES
PROGRAMMABLE ODOMETER/MODULES INPUT
RESETTING OF THE INITIAL CONDITIONS PROGRAMMED AT DEFAULT
DIGITAL IMMOBILIZER CENTRAL UNIT REPLACEMENT
The input is delayed on the system activation (for the first seconds, then it becomes
instantaneous). It can have an initial delay of (standard) or of , and be
referred to (it signals the alarm when it “receives” ground standard setting) or to
(it signals the alarm when receiving a positive signal).
The presetting depends on the vehicle and on the paired accessories.
It can be directly connected to the internal roof lamp wire even if it switches on/off gradually.
The same delay of 30 / 50 seconds preset for the doors buttons is used for the ADDITIONAL or
the DUAL ZONE modules input.
This input can function as follows:
- As input for the
- As (hyperfrequency, anti lifting, etc.).
It simplifies the connection, reduces the use of the decoupling diodes and allows to
understand/identify the alarm cause (differentiated signaling).
The delayed time on the activation is of 30 seconds (standard) or 50 seconds, as selected for
the delayed input of the doors buttons.
- .
See PRE-ALARM FROM DUAL-ZONE MODULES
It allows to restore the original condition of the central unit, resetting all the default
programmings.
The installation or the replacement of the immobilizers on the MUX line (for example,
series) don't need any pairing with the central unit.
Also the replacement of the central unit made within the first 20 startings doesn't require any
specific operation.
But after with the same central unit, the engine lock accepts only that code
(different for each central unit) of the central unit.
To keep the same immobilizer replacing only the central unit it is necessary:
To have the MAIN or PERSONAL emergency code of the old alarm central unit installed.
To install the new alarm central unit, with “MUX” exit.
To enter into the INSTALLER programming “alarm central unit replacement”. After 10
seconds of quick LED flashings and BEEPS from the buzzer, the LED flashes slowly: skip to
point 4.
Turn on/off the ignition key one time.
With the LED lit fixed, enter the MAIN or PERSONAL code of the OLD central unit.
At the end the LED is lit fixed.
Disconnect the feeding of the central unit for at least 1 minute.
Feed the system (acousting confirmation, followed by a system desactivation signalling);
then test the equipment.
- If the engine doesn't start or it stops after a few seconds, repeat the procedure from point n.3.
- If the engine stays regularly ON, the procedure has been followed correctly and the
immobilizer, after 20 startings made with the same new central unit, will be paired with it
definitively.
30 seconds 50 seconds
negative
positive
ODOMETER: it detects the vehicle's speed for the speedometer, the
safety lock and the anti-car jacking.
delayed input for additional modules
Pre-alarm from DUAL-ZONE modules
.
MED 30.x
21 startings
1
2
3
4
5
6