EasyManua.ls Logo

MED 2200 - Security Feature Programming

MED 2200
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROGRAMMINGSFORTHEINSTALLER
ULTRASONIC SENSOR SENSITIVITY
2
3 Medium - standard setting
4
SETTING OF THE DOORS LOCKING/UNLOCKING TIME
5 0,8 seconds locking / unlocking - standard setting
6
7
8
DOORS LOCKING ACTIVATION/TIMED STATUS
9 Delayed - standard setting
FIXED/TIMED STATUS SIGNAL
10 Fixed - standard setting
TIME OF THE STATUS SIGNAL IF TIMED
11 10 seconds - standard setting
12
13
DOUBLE CONTROL FOR DOORS LOCKING
14 Cutting out - standard setting
DELAYED INPUT OF DOORS BUTTON TO POSITIVE/NEGATIVE
15 Negative - standard setting
DELAYED TIME ON ACTIVATION BUTTONS AND MODULES INPUT
16 30 seconds - standard setting
AUTOMATIC ACTIVATION OF THE ENGINE LOCK
17 Cutting out - standard setting
WAY TO ACTIVATE THE AUTOMATIC ENGINE LOCK
18 Immediate - standard setting
ALARM OUTPUT
19 Intermittent - standard setting
TEST
20
21
22
ULTRASONIC SENSOR
23 Activation - standard setting
ANTI-TAMPERING OF THE ULTRASONIC SENSOR
24 Activation - standard setting
ODOMETER/MODULES PROGRAMMABLE INPUT
25
26
27 Odometer - standard setting
ABSORPTION SENSOR
28 Cutting out - standard setting
ANTI-CAR JACKING
29 Cutting out - standard setting
30 Manual - standard setting
31 Short - standard setting
DIRECTION INDICATORS CONTROL
32
33 Single negative control with starting and final blinking IMPULSE - standard setting
34
RESET OF THE INITIAL CONDITIONS PROGRAMMED AT DEFAULT
35
36 Cutting out - standard setting
MED 30.x DIGITAL IMMOBILIZER
40 MED 30
Low
High
3 seconds locking / unlocking
10 seconds at locking - 0,8 seconds at unlocking
30 seconds at locking - 0,8 seconds at unlocking
Simultaneous /
Timed (10 sec. Standard) /
30 seconds
45 seconds
Activation /
Positive /
50 seconds /
Activation /
Delayed to 5 minutes /
Fixed /
Modules
Buttons
Ultrasonic sensor
Cutting out /
Cutting out /
Delayed alarm input for modules
Pre-alarm input for dual-zone modules
Activation /
Activation /
Automatic /
Activation times: Long /
With 2 wires by relays separated channels (right/left side separated) - “USUALCONNECTION”
Single negative CONTINUOUS control
Standard values setting
It's active also when the door is opened with started engine
Activation /
(on MUX line)
Replacement of the alarm central unit paired with the immobilizer of the series
AUTOMATIC ANTI HI-JACK FUNCTION:
28

Table of Contents