Board high temperatureBoard high temperature
BMS temperature > 65°C.
Resistors high temperatureResistors high temperature
Resistor temperature > 85°C.
Battery error
Possible causes of the error message:
a. Zero battery capacity.
b. Lowest cell voltage less than 3.3 V
c. Permitted discharge current exceeded (100 A)
d. Permitted charging current exceeded (approx. 7 A)
e. Permitted battery temperature exceeded (55 °C)
f. Permitted BMS temperature exceeded (55 °C)
Battery warning
Warning, battery error. Possible causes:
a. Lowest cell voltage less than 3.2 V.a. Lowest cell voltage less than 3.2 V.
b. Critical battery temperature exceeded (65 °C).b. Critical battery temperature exceeded (65 °C).
c. Critical ambient temperature exceeded (65 °C)c. Critical ambient temperature exceeded (65 °C)
d. Critical BMS temperature exceeded (65 °C)d. Critical BMS temperature exceeded (65 °C)
e. Critical balancer temperature exceeded (85 °C)e. Critical balancer temperature exceeded (85 °C)
Canbus driver errorCanbus driver error
Control board communication error
Canbus display errorCanbus display error
Display communication error
Canbus BMS errorCanbus BMS error
Battery control communication error.