9
SALT CHLORINATOR On/Off/Auto: ON/Off Switch. In Auto mode, the
chlorinate is operated by the timer setting
Light On/Off: Switch for underwater light connected to the control unit (For
certain model)
System Control: Adjust the chlorine product of the chlorinator, for example,
for the control unit turned on for 8 hours
Set at 100% - The salt cell operated at 8 hours
Set at 50% - The salt cell operated at 4 hours
Set at 25% - The salt cell operated at 2 hours
Display: Show the percentage of the chlorine production
Winter Mode Switch and On/ Off LED: Turn on to change the chlorine
production at 85% .
Cell Polarity LED: Show the polarity of the electrodes; the polarity of the
electrode will shifted every 8 hrs of operation, so as to clean the deposition
on the electrode.
Timer: Used to set the program to turn on and off the control unit
automatically. (SSC-T AND SSC-TLT ONLY)
Stand-By LED: Turn on when chlorinate is in stand-by mode, When the
chlorinator is turn on, the standby LED will go off after 35 sec.
No Flow LED: Turn on if there is no water flow, if there is no water flow, the
pump and salt chlorinator will stop automatically.
TIMER OPERATION for SSC-
TLT & SSC-T Series Only
1. Turn the outer clock face until the time of
the day is aligned with the clock at the
center of the timer
2. The 24-hour dial has 15 minutes division.
The timer can be programmed by pushing
the captive trippers to the outer ring
position for the entire period that the load
is to be turn ON.
3. The timer clock will rotate with time; the
chlorinator will be turned on automatically
if its captive tripper is pushed outward.
English