4. How to set the communication for multiple brands of inverters by host
computer
4.1 Factory default setting of inverter communicate, RS485 is Growatt, CAN is DEYE,
SUNSYNK,LUXPOWER. If need switch to other protocol, the RS232 crystal head of the
communication cable is inserted into the battery communication port, the USB end is inserted into
the computer;
4.2 Open the BMS tool
4.3 Select the corresponding inverter protocol from BMS Tool, click setting(),then restart
the BMS ON/OFF , the inverter protocol will be set successful;
4.4 RS485 protocol and CAN protocol as below: