Megger MFT1835 User Manual

Megger MFT1835
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MFT1800 series
Multifunction testers
User Guide

Table of Contents

Other manuals for Megger MFT1835

Question and Answer IconNeed help?

Do you have a question about the Megger MFT1835 and is the answer not in the manual?

Megger MFT1835 Specifications

General IconGeneral
TypeMultifunction Tester
Frequency Range45 Hz to 65 Hz
DisplayBacklit LCD
IP RatingIP54
Safety StandardsIEC 61010-1, IEC 61557
Insulation Test Voltages250V, 500V, 1000V
Insulation Resistance Range0.01 MΩ to 1000 MΩ
Loop Impedance Range0.01 Ω to 20 Ω
RCD Test Current10 mA, 30 mA, 100 mA, 300 mA
Voltage Measurement Range0 to 600 V AC/DC
PSC/PFC Range20 kA

Summary

Safety

Safety Warnings

Important safety precautions and warnings for using the instrument.

Live Earth Safety Precautions

Specific safety measures when dealing with 'live' earth connections.

Instrument Operation

General Operation Procedures

Basic operating procedures applicable to all MFT1800 models.

Measurement Functions

Making a Voltage Measurement

Step-by-step guide to performing voltage measurements with the instrument.

Continuity and Resistance Testing

Nulling Test Lead Resistance

Procedure for zeroing test lead resistance for accurate continuity measurements.

Making a Continuity Measurement

Step-by-step guide to performing continuity tests.

Insulation Resistance Testing

Making an Insulation Measurement

Step-by-step guide to performing insulation resistance tests.

Loop Impedance Testing

L-PE Loop Test Options

Details on 3Lo, 2Hi, and 2Lo loop test options in L-PE mode.

Zs and Zdb Loop Measurements (No RCD)

Performing Zs and Zdb loop tests without an RCD in circuit.

Earth Loop Measurements with RCD

Testing Earth Loop impedance on circuits protected by an RCD.

Prospective Fault Current & Short Circuit Calculation

Calculating PFC and PSCC during loop impedance tests.

Confidence Meter for Non-Trip Loop Tests

Using the Confidence Meter for accurate 3Lo loop impedance measurements.

RCD/GFCI Testing

Earth Resistance Measurement

Setup Options and Configuration

Configuring Instrument Settings

How to adjust instrument settings for optimal testing.

Safe Working Practice (Appendix D)

Ensuring Safe Instrument Use

Important practices for safe operation and testing with the instrument.

Instrument Specifications

Accuracy Specifications

Detailed accuracy specifications for various instrument functions.

Insulation, Continuity, and Loop Test Specifications

Technical specs for insulation, continuity, and loop impedance tests.

RCD, Voltage, Frequency, and Earth Test Specifications

Technical specs for RCD, voltage, frequency, and earth testing.

Repair and Warranty Information

Calibration, Repair, and Spare Parts

Procedures for instrument calibration, repair, and obtaining spare parts.