EasyManuals Logo

Megger TDR2000 User Manual

Megger TDR2000
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Except where otherwise stated, this specification applies at an
ambient temperature of 20°C.
Ranges: 50m, 100m, 200m, 400m,
1km, 2km, 4km, 8km, 16km.
Resolution: 0.1m up to 200m
0.2m up to 400m
0.1% of range above 400m
Measurement Accuracy: 0.1% of Range
[Note – The measurement accuracy is for the indicated cursor
position only and is conditional on the velocity factor being
correct.]
Input Protection: The inputs will withstand 150Vdc or
150Vac up to 500Hz.
Output pulse: 14 volts peak to peak into open
circuit, 7 volts peak to peak
into 120
Pulse width user selectable:
50m range: 20ns, 40ns, 60ns, 80ns, 100ns
100m range: 20ns, 50ns, 800ns, 100ns, 140ns
200m ranges: 20ns, 60ns, 100ns, 140ns, 200ns
400m range: 40ns, 80ns, 160ns, 200ns, 400ns
1km range: 80ns, 160ns, 260ns, 500ns, 1µs
2km range: 160ns, 260ns, 500ns, 1µs, 2µs
4km range: 250ns, 500ns, 1µs, 2µs, 4µs
8km range: 500ns, 1µs, 2µs, 4µs, 8µs
16km range: 1µs, 2µs, 4µs, 8µs, 16µs
Gain: 0 to 90dB in steps of 6dB
Velocity Factor: Variable from 0.300 to 0.999 in steps
of 0.001
Repetition rate: Burst of 256 pulses every 1 or 10
seconds.
Output impedance: Balanced 120
Balance Adjustment: 0 to 120
Update Rate: Once per second.
Power Down: Automatic after 5, 10 or 15 minutes
with no key press, user selectable.
Backlight: Stays on for 1, 2 or 5 minutes when
activated, user selectable.
Specification
14

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Megger TDR2000 and is the answer not in the manual?

Megger TDR2000 Specifications

General IconGeneral
BrandMegger
ModelTDR2000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals