Rev 14.14.2036
Mellanox Technologies
17
591240 Description: Any local (internal) loopbacked packet is counted by the Vport counters,
although Vport counters should count only traffic that crosses the Vport.
WA : N/A
Keywords: Virtualization
597718 Description: Vport number in virtual trap might be reported incorrectly
WA : N/A
Keywords: Virtualization
689471 Description: Single FTE that catches both untagged and prio-tagged packets (by giving an
FTE with match_value.vlan_tag = 0 and match_value.vid = 0) is currently not supported.
WA : N/A
Keywords: Ethernet Network
688670 Description: Configuring the SM with VL weight 0 on some VL, and running traffic on it,
causes the driver to hang during unload.
WA : Cold power-cycle the server
Keywords: QoS
677359 Description: When Clause 74 Fire-Code FEC is active, and there are FC corrected errors,
both the
FC_correctable counter and the FC_uncoreectable counter are increment.
WA : N/A
Keywords: Clause 74 Fire-Code FEC, Counters
691387/
691415
Description: In a Multihost setup, when running a single TCP stream, you might experience
sub optimal throughput.
WA : Use multiple streams to reach optimal results
Keywords: Multihost setup, Performance, TCP stream
693832 Description: In a Multihost InfiniBand setup, Host#0 should be loaded first and unloaded
last.
Currently the device does not support reboot/stop_driver/flr on Host#0 while other
hosts are active.
Note: Host0 can be selected by changing the INI
WA : N/A
Keywords: Multihost InfiniBand
Table 12 - Known Issues (Sheet 4 of 5)
Internal Ref. Issue