The following table describes known issues in this firmware release and possible workarounds.
Table 12 - Known Issues (Sheet 1 of 5)
Internal Ref. Issue
- Description: To raise links with platforms based on the following ICs, comply with the fol-
lowing firmware version requirements:
• ConnectX®-3 - 2.32.5100
• SwitchX® - 9.2.7300 (or MLNX-OS 3.3.5006)
WA : N/A
Keywords: Interoperability
682518 Description: Interoperability issue between ConnectX-4 or ConnectX-4 Lx adapter cards and
ConnectX-2 adapter card when trying to raise a 10GbE link.
WA : N/A
Keywords: Interoperability
- Description: PCIe capability “Device S/N” returns false value.
WA : N/A
Keywords: PCI
- Description: When the link is Gen2, entering or exiting L1 state may cause bad CRC or
DLLP indication.
WA : N/A
Keywords: PCI
600534 Description: Configuration space power management capability PME_EN cannot be set.
WA : N/A
Keywords: PCI
- Description: PF direct pass-through is not supported (since PF FLR is not supported)
WA : N/A
Keywords: PF direct pass-through
687113 Description: Some Port Control Register do not return to the default value after the last port
owner host restarts the driver.
WA : Reboot or reset the driver.
reboot / mlxfwreset
Keywords: PRM