EasyManua.ls Logo

Mendota FV33I Gen 3 User Manual

Mendota FV33I Gen 3
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
85-03-01058-0 FV33i Gen 3
Installation and Operating Instructions
MODEL NO. AA-11-03119 FV33I Gen 3 FULLVIEW DIRECT VENT GAS FIREPLACE INSERT HEATER
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result causing property damage, personal injury, or
loss of life.
AVERTISSEMENT. Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d'incendie ou d'explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs
ou liquids inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gasses unless a
certified kit is used.
Cet appareil peut être installé dans une maison
préfabriquée (É.-U. seulement) ou mobile déjà installée à
demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de
gaz indiqués sur la plaque signalétique. Une trousse de
conversion est fournie avec cet appareil.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and must be installed.
Une barrière conçue pour réduire le risque de brûlures
du verre chaud est fournie avec cet appareil et doit être
installée.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mendota FV33I Gen 3 and is the answer not in the manual?

Mendota FV33I Gen 3 Specifications

General IconGeneral
BrandMendota
ModelFV33I Gen 3
CategoryIndoor Fireplace
LanguageEnglish

Summary

READ ME FIRST

GENERAL INFORMATION

SAFETY AND WARNING INFORMATION

General safety and warning information, including permit and inspection requirements.

SAFETY WARNINGS

TECHNICAL REFERENCES

GENERAL TECHNICAL REFERENCES

General technical references for installation, including inspections and curing procedures.

MECHANICAL TECHNICAL REFERENCES

INSTALL ONLY IN WOODBURNING FIREPLACES

Requirement to install the insert only inside masonry or factory-built ZC wood burning fireplaces.

CLEARANCES TO COMBUSTIBLE SIDE WALLS

Requirements for clearances to combustible side walls and reduction methods.

CLEARANCES TO COMBUSTIBLE MANTELS

Guidelines for clearances to combustible mantels and mantel profiles.

HEARTH PAD REQUIREMENT

Requirements for hearth pad protection, including R-value and dimensions.

ELECTRICAL TECHNICAL REFERENCES

AC POWER REQUIREMENTS

Requirements for AC power supply, including planning and connection options.

PLUMBING TECHNICAL REFERENCES

GAS SUPPLY REQUIREMENTS

Requirements for gas supply, including pressure, sizing, shutoff valves, input rate verification, and high altitude de-rating.

INSTALLATION INSTRUCTIONS

INSTALLATION CHECKLIST

Comprehensive checklist for installers to follow during fireplace insert installation.

NATURAL GAS TO LPG CONVERSION

Detailed procedure for converting the fireplace from natural gas to LPG, including parts and steps.

VENTING

Instructions for venting systems, including adapter removal, liner installation, cap attachment, and sealing.

INSERT BODY INSTALLATION

Step-by-step guide for installing the insert body into the fireplace cavity.

LIGHTING CHECKLIST

Checklist to ensure proper lighting and operation before final use.

HOMEOWNER INFORMATION

OPERATING INFORMATION

Information on operating the fireplace, including using the remote control and its functions.

REMOTE CONTROL OPERATING INSTRUCTIONS

Detailed explanation of remote control functions, icons, and operation for turning the fireplace on/off and adjusting settings.

FIRST TIME LIGHTING INSTRUCTIONS

Instructions for the initial lighting of the fireplace, including safety precautions.

MAINTENANCE INFORMATION

REQUIRED PERIODIC INSPECTIONS

Steps for periodic inspections of the vent system, pilot, burners, and flames.

REQUIRED ANNUAL MAINTENANCE

Procedures for annual maintenance, including cleaning, inspections, and checks of components.

WARRANTY QUALIFICATION AND SERVICE

FINAL INSTALLATION AND HOMEOWNER CHECKLIST

Checklist to verify proper installation and homeowner training for warranty qualification.

WARRANTY POLICY STATEMENT

Details the limited lifetime warranty coverage and terms for Mendota fireplace products.

CONDITIONS

Conditions, exclusions, limitations of liability, and how to obtain warranty service and register ownership.

Related product manuals