5.4.4. Automac Defrost
At low room temperatures, frost may build up at the evaporator during operaon. The unit will
automacally start defrosng and the POWER LED blinking. The defrost control sequence is as
follows:
A. When the unit operates in the cooling operaon, drying operaon, the ambient temperature
sensor senses the evaporator coil temperature is below -1°C, aer the compressor will stop
operang for 10 minutes or the coil tempe
rature up to 7°C, the unit restart to cool operang
mode.
5.4.5. Overload Protecon
In the event of a power loss, to protect the compressor there is a 3-minute delay unl the
compressor restarng.
5.5 DRAINAGE
Manual drainage:
1) When the machine stops aer the water is full, please unplug the power plug.
Notes: Please move the machine carefully, so as not to spill the water in the water pan at the boom
of the body.
2) Place the water container below the side water outlet behind the body.
3) Unplug the water plug, the water will automacally ow into the water container.
Notes:
1. Keep the water plug properly.
2. During drainage, the body can be lted slightly backwards.
3. If the water container cannot hold all the water, before the water container is full, stu the water
outlet with the water plug as soon as possible to prevent water from owing to the oor or the
carpet.
4) When the
water is discharged, stu the water plug.
Press UP/DOWN repeatedly until the LED shows ‘00’.
Note: when press POWER will also exit the timer setting.

37