Section 6 - Troubleshooting
Page 92 90-8M0113856 eng DECEMBER 2015
Possible Cause Remedy
Loose or dirty electrical
connections or damaged
wiring.
Check all associated electrical connections and wires (especially battery cables). Clean and
tighten faulty connection. Repair or replace wiring.
Power Trim Does Not Operate (Motor Operates but Sterndrive Unit Does Not Move)
Possible Cause Remedy
Trim pump oil level low. Fill pump with oil.
Drive unit binding in gimbal ring. Check for obstruction.