locations in another M2000PE, or to a PC running the WIN-GT/SYSTEM programme. It is
possible to add or delete serial numbers using the PC and transfer these to the M2000PE,
instead of directly entering each device using a reader or through the receiver.
Connect the M2000PE to another M2000PE using the RJ-11 plug. Connect to a PC
using screw terminals 21 and 22 (see page 5) and INT485C.
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.
c) Scroll using INC & DEC to display F9.
d) Press VAL to confirm. The lowest required location for transfer will appear on
the display. (Default is 0.001) Note the left decimal point is on, indicating that
this location is the lower bound of the range.
e) If required, scroll using INC & DEC to alter the lowest location to be transferred,
e.g. 0.020
f) Press VAL to confirm. The highest required location will appear on the display.
(Default is 0001.) Note the right decimal point is on, indicating that this location
is the upper bound of the range.
g) Scroll using INC & DEC to display the highest location for transfer, e.g. 0029.
h) Press VAL to confirm. The display will show _ _ _ _
i) Press VAL again to confirm the transfer. The display will flash _ _ _ _ while the
codes in all locations from the lower to the upper selections are being trans-
ferred. Display will return to the function selection menu.
j) Simultaneously press INC & DEC to exit programming mode.
Note that pressing FUN will revert the unit back to the function selection menu unless data
transfer has commenced.
Note: Data will only show on the PC once it has been copied from the M2000PE module.
Data entered into the PC will only show on the M2000PE module once it has been copied
to the module.
This is achieved from the ‘memory’ menu, ‘copy’ option, ‘file to module’, or ‘module to file.
F10: Memory mode
Three different relay assignment options for wireless devices are available on the M2000PE
unit: F, H, & P. Note that using H or P option will result in all code stored in all locations to be
deleted.
F This is the default mode, where relays are activated according to their assign-
ment in F3 and F4. Namely:.
All locations activate relay 1 from a particular wireless channel, set up using F3
All locations activate relay 2 from a particular wireless channel, set up using F4
This function is useful to allow all users to operate each relay from the same
channels on their remotes.
One channel can operate both relays, or different channels can operate each
relay.