H This mode is to allow some restriction on user access to some doors. Namely:
Locations 0001 to 1000 activate relay 1 only; select which radio channel using
F3
Locations 1001 to 2000 activate relay 2 only; select which radio channel using
F4
If one wireless device is to operate two relays, then it must be assigned to two
locations, for example:
Location 0001, channel 1 (button 1), relay 1
Location 1001, channel 2 (button 2), relay 2
And so a user who is allowed to access only one relay should only be stored in
only one location.
P This anti-pass back function is useful to prevent multiple entries without exiting
using the same card.
Card must be assigned to relay 1 and to relay 2.
Relays must be activated in sequence by the same card.
To select F, H, or P options:
a) Simultaneously press INC & DEC to enter programming mode.
b) Press FUN to access the function selection menu.
c) Scroll using INC & DEC to display F10.
d) Press VAL to confirm. The display will show the current mode selected, e.g. F
e) Scroll using INC & DEC to display F, H, or P
f) Press VAL to confirm. The display will return to the function selection menu.
g) Simultaneously press INC & DEC to exit programming mode.