INTRODUCTION
The Genetix Remote Handheld User Interface is a device that allows you to completely
interact with your Genetix controlled Feeder or Scale in a wireless manner. It is intended
to provide you a means to temporarily control your feeder for calibration, maintenance,
or diagnostic purposes in the absence of a locally mounted, wired User Interface.
The Remote User Interface is battery powered for maximum portability. It operates
wirelessly using the Bluetooth protocol and can connect to any Merrick feeder within
range, so only one Remote User Interface is needed for any number of Merrick feeders.
Note: Each Merrick feeder to which you wish to connect must be equipped with its own
optional Bluetooth interface.
The Remote User Interface utilizes the exact same menu system as the Genetix LCD
Interface, and detailed instructions for this can be found in the appropriate Merrick
Operating Manual. The following sections in this Manual will instruct you in the proper
use of the Remote User Interface, including connection to Merrick feeders.

Other manuals for MERRICK Genetix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MERRICK Genetix and is the answer not in the manual?

MERRICK Genetix Specifications

Operating Environment IconOperating Environment
maximum ambient temperature50°C (122°F)
minimum ambient temperature-10°C (14°F)
Power IconPower
supply voltage24 VDC +/- 1V
power consumption8W nominal, 12W maximum
power dissipation5W nominal, 10W maximum
Loadcell Inputs IconLoadcell Inputs
excitation voltage5 VDC
excitation current300mA (max)
Tachos IconTachos
supply voltage5 VDC
supply current400mA, maximum (total)
Analog Inputs IconAnalog Inputs
input impedance (current input)200 ohms
input impedance (voltage input)100Kohms
Digital Inputs IconDigital Inputs
input impedance at 24 VDC7.5 KΩ
input impedance at 120 VAC64 KΩ
input impedance at 240 VAC120 KΩ
Digital Outputs IconDigital Outputs
contact ratings (AC)5A, 250 VAC
contact ratings (DC)5A, 30 VDC
External Mechanical Totalizer IconExternal Mechanical Totalizer
contact ratings (AC)120mA, 240 VAC
contact ratings (DC)120mA, 24 VDC