EasyManuals Logo

MERRICK Genetix Safety, Installation, Operation And Maintenance Instructions

MERRICK Genetix
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Page 8 of 15
Standard Operation
Powering up the Unit
Power up the Remote User Interface by momentarily pressing the power button. The
power button is the round orange button as shown below:
The screen should light up, and you should see the Merrick identification screens
followed by the Connection Menu (see below).
Powering down the Unit
Turn off the Remote User Interface by pressing and holding the power button until the
display goes blank. This takes 1- 2 seconds. You will see a “powering down” graphic
while the unit powers down. Note: Powering down the unit disconnects the Bluetooth
connection if there is one.
Connection Menu
When powered up, you should see the Connection Menu. This menu allows you,
using the Bluetooth protocol, to find and connect to the correct Merrick Feeder and/or
to manage the stored list of feeders utilizing one of the following options:

Other manuals for MERRICK Genetix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MERRICK Genetix and is the answer not in the manual?

MERRICK Genetix Specifications

Operating Environment IconOperating Environment
maximum ambient temperature50°C (122°F)
minimum ambient temperature-10°C (14°F)
Power IconPower
supply voltage24 VDC +/- 1V
power consumption8W nominal, 12W maximum
power dissipation5W nominal, 10W maximum
Loadcell Inputs IconLoadcell Inputs
excitation voltage5 VDC
excitation current300mA (max)
Tachos IconTachos
supply voltage5 VDC
supply current400mA, maximum (total)
Analog Inputs IconAnalog Inputs
input impedance (current input)200 ohms
input impedance (voltage input)100Kohms
Digital Inputs IconDigital Inputs
input impedance at 24 VDC7.5 KΩ
input impedance at 120 VAC64 KΩ
input impedance at 240 VAC120 KΩ
Digital Outputs IconDigital Outputs
contact ratings (AC)5A, 250 VAC
contact ratings (DC)5A, 30 VDC
External Mechanical Totalizer IconExternal Mechanical Totalizer
contact ratings (AC)120mA, 240 VAC
contact ratings (DC)120mA, 24 VDC