| AC Voltage Accuracy | ±(1.0% + 3 digits) |
|---|---|
| DC Current Accuracy | ±(1.0% + 2 digits) |
| AC Current Accuracy | ±(1.5% + 3 digits) |
| Resistance Accuracy | ±(0.8% + 2 digits) |
| Diode Test | Yes |
| Frequency Range | 10Hz to 10MHz |
| Battery Type | 9V (6F22) |
| DC Current Ranges | 10 A |
| AC Current Ranges | 10A |
| Continuity Test | Yes |
| Display | 4000 counts |
| Safety Rating | CAT III 600V, CAT II 1000V |
General precautions and safety measures for using the instrument.
Details on the various built-in protection devices of the multimeter.
Information on the safety features and mechanisms integrated into the instrument.
Details on the warranty terms and conditions for the multimeter.
Instructions and recommendations for the maintenance of the multimeter.
Guidelines for unpacking new equipment and repacking for return or storage.
Description of the nine-position rotary selector switch and its functions.
Overview of the ten-key keypad and its operational capabilities.
Details about the multimeter's display, including figures and bargraph.
Information regarding the power supply of the instrument, including battery type and life.
Description of the input terminals used for connecting measuring leads.
Instructions for correctly connecting the black and red test leads.
Procedure for turning on the multimeter and preparing it for measurements.
How to manually or automatically switch off the multimeter.
Information on adapting instrument configuration for specific measurement environments.
Procedures for maintaining the multimeter, including fuse and battery replacement.
Functionality of the SEL/ON key for switching on and accessing secondary functions.
Usage of the RANGE key for selecting measurement ranges and autoranging.
Operation of the REL key for relative measurements and reference value adjustment.
Function of the Pk +/- key for fast positive or negative peak measurements.
How to use the HOLD key for fixing display values and accessing autostore.
Function of the ZOOM key for expanding bargraph readout and adjusting references.
Operation of the SURV key for surveillance mode (MIN, MAX, AVG) measurements.
Usage of the Hz key for frequency, duty cycle, and pulse measurements.
Function of the PRINT key for sending data to a printer or PC.
Operation of the key for activating display backlighting.
Technical specifications for DC voltage measurements, including ranges, accuracy, and protection.
Technical specifications for AC voltage measurements (AC and AC+DC).
Technical specifications for DC current measurements, including ranges, accuracy, and voltage drop.
Technical specifications for AC current measurements (AC and AC+DC).
Specifications for resistance measurements and continuity testing, including ranges and current.
Technical specifications for capacitance measurements, including ranges, accuracy, and current.
Specifications for measuring diode threshold voltage, including measurable voltages and current.
Details on the dB function, including resolution, error, and measurement range.
Specifications for the resistive power function, including measured function, accuracy, and display unit.
Technical specifications for frequency measurements, including ranges, accuracy, and sensitivity.
Specifications for duty cycle measurements, including resolution, duration, and absolute error.
Details on positive or negative pulse counting, including minimum duration and trigger limit.
Specifications for measuring positive or negative pulse width, including resolution and accuracy.
Information about accessories supplied with the multimeter and optional accessories.