Technical data Page 10
3 Technical data
Range ARS 2302 FS ARS 2305 FS ARS 2310 FS
Metronix part number
with FBA module
9200-2302-20 9200-2305-20 9200-2310-20
Metronix part number
with STO module
9200-2302-22 9200-2305-22 9200-2310-22
Metronix part number
with MOV module
9200-2302-23 9200-2305-23 9200-2310-23
Power connector set 9200-0230-20
Signal connector set 9200-0200-00
FBA module 9200-0150-00
STO module 9200-0151-00
MOV module 9200-0152-00
Ambient conditions and qualification:
Admissible temperature ranges Storage temperature: -25°C to +70°C
Operating temperature: 0°C to +40°C
+40°C to +50°C at reduced power 2,5%/K
Admissible installation height Mounting height maximum 2000 m above msl, above 1000 m
above msl with power reduction 1% per 100 m
Humidity Relative humidity up to 90%, not bedewing
Protection degree
IP20
Protection class
I
Pollution degree
2
CE conformity
Low-voltage directive:
EMC directive:
2006/95/EC
verified by application of the harmonised standard EN 61800-5-1
2004/108/EC
verified by application of the harmonised standard EN 61800–3
cULus certification Listed according to UL 508C, C22.2 No. 274-13
Dimensions and weight:
Dimensions: H*W*D 334,5 x 69 x 245,5 mm
Weight c. 3,7 kg
Performance data [X9]:
Supply voltage 3 x 230 ... 480 VAC [+/- 10%], 50…60 Hz
Alternative DC supply 60 ... 700 VDC