EasyManua.ls Logo

Mettler Toledo Seven2Go S3 User Manual

Mettler Toledo Seven2Go S3
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ME
TTLER TOLEDO
Seven2Go
Cal
S3
Operating Instructions
Seven2Go™ Conductivity Meter

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mettler Toledo Seven2Go S3 and is the answer not in the manual?

Mettler Toledo Seven2Go S3 Specifications

General IconGeneral
Measurement ParameterpH, mV, Temperature
pH Range-2.00 to 20.00
pH Resolution0.01
pH Accuracy±0.01
pH Relative Accuracy±0.01
mV Resolution0.1
mV Relative Accuracy±0.2
Temperature Range-5.0 to 105.0 °C
Temperature Resolution0.1 °C
DisplayLCD
CalibrationUp to 5 points
IP RatingIP67
Data ExportUSB
Temperature Relative Accuracy±0.5 °C
Memory200 data sets

Summary

Introduction

Safety Measures

Definition of Signal Warnings and Symbols

Explains signal words and warning symbols used in the manual.

Product Specific Safety Notes

Provides specific safety guidelines for the instrument's intended use and location.

Design and Function

Instrument Overview and Controls

Details instrument components, sensor connections, and control keys.

Display and Icons

Explains the meaning of various icons displayed on the instrument screen.

Setup Menu Navigation and Structure

Guides users on navigating the setup menu and outlines its structure.

Measurable Parameters

Lists the different parameters that the conductivity meter can measure.

Putting into Operation

Scope of Delivery

Lists the items included in the product package.

Battery Installation

Provides step-by-step instructions for installing the instrument's batteries.

Sensor Connection

Explains the procedure for connecting an ISM sensor to the meter.

Optional Equipment Installation

Details mounting of electrode holder and stabilizing unit.

Wrist Strap Installation

Illustrates the process of attaching the wrist strap for security.

Switching Instrument On and Off

Describes how to power the instrument on and off.

Operation of the Instrument

Calibration Procedures

Explains how to determine cell constant and perform calibration.

Performing a Calibration

Details the steps to perform a calibration with sensor and standard.

General Settings and Endpoint Formats

Covers general settings for stability and measurement endpoint formats.

Measurement Settings Overview

Covers interval reading and reference temperature settings.

Temperature Correction and Alpha-Coefficient

Details how to set temperature correction and alpha-coefficients.

TDS Factor and Conductivity Ash Measurement

Explains TDS factor setting and conductivity ash measurement methods.

Sample Measurement Procedures

Guides on performing conductivity, TDS, salinity, and resistivity measurements.

Using the Memory for Results

Explains storing, recalling, and clearing measurement results.

Power Management and Self-Test

Covers hot power settings, instrument self-test, and factory reset.

Maintenance

Cleaning the Housing

Provides instructions on how to clean the instrument's housing.

Error Messages and Troubleshooting

Lists common error messages and their solutions.

Disposal Instructions

Explains the proper disposal procedures for the instrument.

Product Portfolio

Accessories

Technical Data

Appendix

Conductivity Standards Data

Lists conductivity standard values at different temperatures.

Temperature Correction Factors

Provides temperature correction factors for non-linear conductivity correction.

Measurement Formulas and Factors

Covers alpha-values, salinity formula, and TDS conversion factors.

Conductivity Ash Measurement Methods

Details formulas for conductivity ash measurement for refined sugar and raw sugar.

Related product manuals