EasyManua.ls Logo

Meyer Sound QUICKFLY M Series - Using the MG-1 D Grid to Transition from M2 D to 3 UPA-2 P Loudspeakers (40° Splay)

Meyer Sound QUICKFLY M Series
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M1D Rigging Grids and Accessories
PN: 05.115.001.01 B
Page 12 of 24
Meyer Sound Laboratories Inc.
www.meyersound.com
T: +1 510 486.1166
F: +1 510 486.8356
M1D Rigging Grids and Accessories
PN: 05.115.001.01 B
Page 13 of 24
Meyer Sound Laboratories Inc.
www.meyersound.com
T: +1 510 486.1166
F: +1 510 486.8356
USING THE MG-1D GRID TO TRANSITION FROM M2D TO 3 UPA-2P LOUDSPEAKERS (40° SPLAY)
This conguration provides 0° to 7° of down tilt in 1-degree increments for a downll of UPA-2P compact narrow
coverage loudspeakers when transitioning from an M2D array. A total of 110 degrees of horizontal coverage is
provided by the UPA-2P array. The UPA-2Ps can also be own independently with the MG-1D grid from a single pick-
up point on the frame’s center bracket.
To assemble this conguration, lift the D-Rings on the UPA-2Ps and guide them into each hole marked with a triangle
on the MG-1D grid. Fasten by fully inserting the quick release pins (QRPs) into the appropriate holes in the grid while
securing the D-Rings. The MG-1D grid can then be attached to the M2D system using the M2D CamLinks, M2D front
links and M2D 5/16” QRPs.
Maximum Load:
Triangle-marked UPA-2P pick-up points.
7:1 safety factor: 2 rows of (3) UPA-2Ps
462 lbs (209.5 kg)
CAUTION: When using
an MG-1D multipurpose
grid as a top grid to y a UPA-
2P array, it must always be
supported by at least one pick-up
hole from the main frame’s center
bracket. The extension frame may
be used as a secondary pick-up
location for tilting the array or
spreading the load between two
points.
CAUTION: When ying an
MG-1D grid and UPA-2P
array beneath an M2D array,
include the weight of the grid and
the weight of the UPA-2P array in
your total weight calculations. Do
not exceed the weight rating of
the primary supporting grid.
WARNING: The leveling feet must always be detached from the MG-1D grid before ying a system.
Unscrew the entire assembly, including the threaded leg, and remove completely.