EasyManua.ls Logo

Meyer Sound QUICKFLY M Series - Using the MG-1 D Grid to Transition from M2 D to 2 MSL-4 Loudspeakers (30° Splay)

Meyer Sound QUICKFLY M Series
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M1D Rigging Grids and Accessories
PN: 05.115.001.01 B
Page 14 of 24
Meyer Sound Laboratories Inc.
www.meyersound.com
T: +1 510 486.1166
F: +1 510 486.8356
M1D Rigging Grids and Accessories
PN: 05.115.001.01 B
Page 15 of 24
Meyer Sound Laboratories Inc.
www.meyersound.com
T: +1 510 486.1166
F: +1 510 486.8356
USING THE MG-1D GRID TO TRANSITION FROM M2D TO 2 MSL-4 LOUDSPEAKERS (3O° SPLAY)
This conguration allows a pair of MSL-4 horn-loaded long throw loudspeakers to be own at a 30-degree splay when
transitioning from an M2D and M2D-Sub array. The MG-1D grid provides from 0° to -7° of tilt in 1-degree increments
between the M2D array and the grid. A total of 65 degrees of horizontal coverage is provided by the MSL-4s. The
MSL-4s can also be own independently with the MG-1D grid from a single pick-up point on the frame’s center
bracket. Other Meyer Sound loudspeakers with the same footprint as the MSL-4 (DF-4 and DS-4P) can be used in this
conguration.
Congure the MG-1D grid to allow the attachment of MSL-4s by pulling out the extension frame to the second pin po-
sition. Lift the D-Rings on the MSL-4s and guide them into each hole marked with a square on the MG-1D grid. Fasten by
fully inserting the quick release pins (QRPs) (C) into the appropriate holes in the grid while securing the D-Rings. The MG-
1D grid can then be attached to the M2D system by using the M2D CamLinks, M2D front links and M2D 5/16" QRPs.
Maximum Load:
Square-marked MSL-4 pick-up points.
5:1 safety factor: 2 rows of (2) MSL-4s
720 lbs (326.5 kg)
CAUTION: When ying an
MG-1D multipurpose grid
and MSL-4s beneath an M2D array,
include the weight of the grid and the
weight of the MSL-4s in your total
weight calculations. Do not exceed
the weight rating of the primary
support grid.
CAUTION: When using the
MG-1D grid as a top grid
to y MSL-4s, it must always be
supported by at least one pick-up
hole from the main frame’s center
bracket. The extension frame may
be used as a secondary pick-up
location for tilting the array or
spreading the load between two
points.
WARNING: The leveling feet must always be detached from the MG-1D grid before ying a system.