EasyManua.ls Logo

MGE UPS Systems GALAXY 6000 User Manual

MGE UPS Systems GALAXY 6000
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MGE
TM
Galaxy
TM
6000:
Specification guide
__________________________________
Parallel UPS, 250 to 3000 kVA*
* Power rating for an N+1 configuration.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the MGE UPS Systems GALAXY 6000 and is the answer not in the manual?

MGE UPS Systems GALAXY 6000 Specifications

General IconGeneral
Frequency50/60 Hz
TopologyDouble Conversion Online
EfficiencyUp to 94%
Humidity0-95% non-condensing
Input Voltage380/400/415 V
Output Voltage380/400/415 V
Battery TypeSealed Lead Acid (SLA)
Typical Recharge Time4 to 8 hours
Operating Temperature0°C to 40°C
Storage Temperature-15°C to 45°C
Dimensions (H x W x D)Varies by model
WeightVaries by model
Communication InterfaceRS-232, SNMP, USB

Summary

2 - Operating Principle

2.1 - Normal Operation

Explains how the UPS operates with a normal AC source available.

2.2 - Battery Operation

Details UPS operation when the AC source fails or is out of tolerance.

2.4 - Parallel Operation

Explains how multiple UPS units operate in parallel, with or without redundancy.

2.5 - Bypass Transfer

Details the automatic transfer of the load to the bypass AC source.

3 - Sizing and General Characteristics

3.2 - Rating

Defines the required load capacity and number/rating of UPS units.

3.3 - Battery Backup Time

Specifies the required battery backup time and service life for the UPS.

4 - AC Sources

4.1 - Normal AC Source

Details the required characteristics of the normal AC power source supplying the UPS.

4.2 - Bypass AC Source

Specifies the required characteristics for the bypass AC power source.

5 - Electrical Characteristics

5.2 - Batteries

Details the type, service life, and sizing requirements for the UPS batteries.

5.3 - Inverter

Specifies the output voltage, frequency, and transient response of the inverter.

5.3.4 - Overload Capacity

5.4 - Static Bypass

5.4.1 - Load Transfer

Details the process and conditions for transferring the load to the static bypass.

5.5 - Discrimination and Short-Circuit Capacity

8 - Protection

8.4 - Battery Protection

Covers protection against deep discharge, independent regulation, and temperature compensation.

11 - Maintainability

14 - Services

14.5 - Replacement Parts

Guarantees the availability of certified original replacement parts for ten years.

15 - Warranty

Related product manuals