Page 19
Installation and Assembly
wireSENSOR, WPS
4. Installation and Assembly
4.1 Precautionary Measures
Do not pull the measuring wire over range.
> Damage to or destruction of the sensor is possible
Do not damage the measuring wire.
Do not oil or grease the measuring wire.
Do not bend the measuring wire.
Do not pull the measuring wire at an angle.
Do not allow to loop the measuring wire around objects.
Fix the sensor with drawn in measuring wire to the target.
Do not loop the measuring wire around parts of the body.
4.2 Sensor Mounting
Model Screws Mounting clamp
MK30 3 x M2.5 yes
MK46 3 x M2.5 yes
MK77 3 x M3 yes
MK60 3 x M3 no
MK88 3 x M4 yes
MK120 3 x M6 no
The sensor does not have to be oriented in a special way.
Choose the installation position so that damage and soiling of the measuring wire is avoided.
Prefer an installation position with measuring wire outlet facing downwards if possible.
This prevents liquids penetrating the measuring wire outlet.
i
Do not let snap the measuring wire!
No warranty by damage through snapping.
Uncontrolled retraction
of the measuring wire is
incorrect!
> Danger of injury
from whiplash effect
of the wire with as-
sembly bolts/clips
> Destruction of wire
and/or of sensor.
Save the wire during
installation work.