Page 31
wireSENSOR, WPS
4.4.2 Voltage Output
Voltage output (U)
Supply voltage 14 ... 27 VDC (non stabilized
1
)
2
4
1
6
8
7
3
5
View
2
Current consumption max. 30 mA
Output voltage
0 ... 10 VDC
Options 0 ... 5 / ±5 V
Output current 2 mA max.
Load impedance > 5 kOhm
Signal noise 0.5 mV
eff
Temperature coefficient ±0.005 % FSO/°C
Einstellbereiche (if supported by the model)
1 = supply
2 = ground
3 = signal
4 = ground
white = supply
brown = ground
green = signal
yellow = ground
Zero ±20 % d.M.
Sensitivity ±20 %
Fig. 15 Table voltage output
1) Non stabilized, measured on the input terminal of the sensor