Installation and Assembly
wireSENSOR, WPS
34.25
(1.34)
22.5
(.89)
ø3
(dia. .12)
2 (.08)
67 (2.64)
77 (3.03)
77 (3.03)
92 (3.62)
ca. 105 (4.14)
5
(.2)
5 (.2) 67 (2.64)
0.6 (.02)
28.5 (1.12)
E: 45.5 (1.8)
E: 51 (2.13)
P: 50 (1.97)
E: ø24 (dia. .95)
P: ø22.5 (dia. .89)
2 (.08)
6 (.24)
89 (3.5)
99 (3.89)
ø8 (dia. .32)
ø4.5 (dia. .18)
Mounting clamp
with Screw M3
Mounting hole
3x ø3.2
(dia. .13)
Fig. 6 Dimensional drawing WPS-...-MK77, with potentiometer or encoder, dimensions in mm (inches), not to
scale
5
(.2)
5 (.2) 67 (2.64)
67 (2.64)
77 (3.03)
34.25
(1.34)
22.5
(.89)
77 (3.03)
ca. 105 (4.14)
92 (3.62)
Mounting hole
3x ø3.2
(dia. .13)
65.5 (2.58)
78.5 (3.1)
2 (.08)
ø3 (dia. .12)
46 (1.81)
89 (3.5)
99 (3.89)
46 (1.81)
38.5
(1.52)
Mounting clamp
with screw M3
ø8 (dia. .32)
ø4.5 (dia. .18)
28.5 (1.12)
0.6 (.02) 2 (.08)
6 (.24)
Fig. 7 Dimensional drawing WPS-...-MK77-CR, with potentiometer and radial cable, dimensions in mm
(inches), not to scale