Cable Specification
9Cable specification
Our system has 2 solutions to unlock the door: Unlock signal from door station or
unlock signal from monitor.(The cable shield wire needs to be grounded)
Cable specification is:
Distance between monitor and door station is less than 30 meters, shielded
4 x 0.5mm² cable is OK;
Distance exceed 30 meters, please choose coaxial cable for video with another
shielded 2*0.5mm² cable or composite coaxial cable.
When using KEY wire from monitor to unlock please use electronic relay as shown
on Page 6.