DOC 4380A
4380A O & M Manual
16
098-00723-000 Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual
[1]
[pps_period] 1.000000000000000e+00
[pps_width] 1.000000000000000e-04
[type] pps
[2]
[pps_period] 1.000000000000000e+00
[pps_width] 5.000000000000000e-01
[type] pps
[3]
[format] A
[signal_word] 3
[type] irig
[4]
[format] B
[signal_word] 0
[type] irig
[OK] 2015-08-05T15:51:30Z
IRIG: Valid DC IRIG Codes are A (000,003,007), B (000,003,007), D002, E002, G002, and
H002. Default is B000. To set the IRIG Code for the individual ports, use the irig command:
4380A> irig [slot#] [port#] [Code A-H] [Code Format <NNN>]
The following example sets the IRIG for Slot 1, Port 3 to A 003.
4380A>irig 1 3 A 003
[OK] 2015-08-05T16:02:16Z
The system will generate an error message if the operator attempts to enter an unsupported or
invalid code.
To verify the settings, use the settings hardware:slots:N command (where N=Slot #) to obtain the
current settings for a particular card.
4380A> settings hardware:slots:1
[4394A]
[ports]
[1]
[pps_period] 1.000000000000000e+00
[pps_width] 1.000000000000000e-04
[type] pps
[2]
[pps_period] 1.000000000000000e-06
[pps_width] 5.000000000000000e-07
[type] pps
[3]
[format] A
[signal_word] 3
[type] irig
[4]
[format] B
[signal_word] 0
[type] irig
[OK] 2015-08-05T16:02:45Z
The system will drop the leading zeros in the signal_word.
To verify the card is working properly, use the status hardware:outputs:slots:N command (where
N=Slot #) to obtain the current settings for a particular card.
4380A>status hardware:outputs:slots:1
[ports]
[1]
[status] good
[2]
[status] good
[3]
[status] good
[4]
[status] good
[power] enabled
[type] 4394A