DOC 4380A
4380A O & M Manual
20
098-00723-000 Jul 2017 Revision 4.0 SyncSystem 4380A O&M Manual
2.5.8 4395B-5 (5MHz)
No programming is required for these modules. These modules will also work in any of the 6 card slots.
To verify these cards are working properly, use the status hardware:outputs:slots:N command (N = slot
number) to obtain the current status for a particular card.
4380A>status hardware:outputs:slots:4
[ports]
[1]
[status] good
[2]
[status] good
[3]
[status] good
[4]
[status] good
[power] enabled
[type] 4395B-5
[OK] 2015-08-05T16:37:43Z
2.5.9 4395B-1 (1MHz)
No programming is required for these modules. These modules will also work in any of the 6 card slots.
To verify these cards are working properly, use the status hardware:outputs:slots:N command (N = slot
number) to obtain the current status for a particular card.
4380A>status hardware:outputs:slots:5
[ports]
[1]
[status] good
[2]
[status] good
[3]
[status] good
[4]
[status] good
[power] enabled
[type] 4395B-1
[OK] 2015-08-05T16:37:43Z
2.5.10 4387A Series (Modulated IRIG/NASA36)
This module provides four Amplitude Modulated (AM) IRIG Outputs or the NASA36 Serial Time Code.
Valid AM IRIG Codes are A (130, 133, 137), B (120, 123, 127), E (111, 112, 121), G (141, 142, 147), and
H (111, 112, 121, 122, 127). The default time code is B120. The 4387A-6V module provides 6 Vpp output
signals.
IRIG: To set the IRIG Code for the individual ports use the irig command:
4380A> irig [slot#] [port#] [Code A-H] [Code Format <NNN>] [epoch]
The following example sets the IRIG Code for Slot 5, Port 3 to G 141 and the epoch off (epoch is
off by default). The epoch option is not required to properly execute this command and can be left
off the command line.
4380A>irig 5 3 G 141
[OK] 2015-08-05T16:35:12Z
The system will generate an error message if the operator attempts to enter an unsupported or
invalid code.
To verify the settings, use the settings hardware:slots:N command (where N=Slot #) to obtain the
current settings for a particular card.
4380A>settings hardware:slots:5