U S E RS M A N U AL

Questions and Answers

  • L
    Lauren ConradAug 13, 2025
    Why is the backup time so short on my Microtek SineWave UPS EB?
    • D
      Dorothy CortezAug 13, 2025
      If you are experiencing short backup time with your Microtek Inverter, check the battery water level and charge the battery with mains for a minimum of 8-12 hours. If the backup time is still insufficient, have the battery checked by authorised service personnel.
  • N
    Nicole SmithAug 16, 2025
    What to do if my Microtek SineWave UPS EB Inverter displays a low battery?
    • M
      martinezashleyAug 16, 2025
      If your Microtek Inverter displays a low battery, it means the battery has discharged. Recharge the battery after the mains restoration.
  • T
    Tommy BarnesAug 20, 2025
    Why does my Microtek Inverter UPS trip frequently in backup mode?
    • R
      Raymond EdwardsAug 20, 2025
      The Microtek Inverter UPS may trip frequently in backup mode because the load is too high. Try reducing the load and then reset the inverter.
  • A
    Anthony LambertAug 25, 2025
    What to do if the fuse is blown in my Microtek SineWave UPS EB?
    • L
      leecourtneyAug 25, 2025
      If the fuse in your Microtek Inverter is blown, check the glass fuse at the rear of the unit. Replace it with a 10Amp rating fuse. If the fuse blows again, it is recommended to call an authorised service engineer.
  • A
    Austin SimpsonAug 28, 2025
    What to do if there is no output from my Microtek SineWave UPS EB Inverter UPS?
    • E
      Elaine BlanchardAug 28, 2025
      If there is no output from your Microtek Inverter UPS, check the circuit breaker or glass fuse at the rear. Reset the circuit breaker. If the fuse is blown, replace it with a 10Amp rating fuse. If the circuit breaker trips or the fuse blows again, call an electrician to check for a short in the load wiring.
  • D
    Danielle HerreraAug 31, 2025
    What to do if Microtek SineWave UPS EB UPS is in UPS mode but there is no power due to overload?
    • W
      williamsbrettAug 31, 2025
      If your Microtek Inverter UPS is in UPS mode but there is no power due to an overload, reduce the load. Then, turn the reset switch on the front panel ON-OFF-ON.
  • Y
    Yolanda RoseSep 4, 2025
    Why does my Microtek SineWave UPS EB Inverter UPS not operate?
    • S
      Stephen WoodSep 4, 2025
      If your Microtek Inverter UPS does not operate, check the battery connections and the mains connections. If the AC glass fuse is blown, check the fuse at the rear and replace it. If there is an internal problem, bypass the UPS and call authorised service personnel.
  • O
    odudleySep 8, 2025
    Why is my Microtek SineWave UPS EB UPS working on battery?
    • S
      Sharon HillSep 8, 2025
      Your Microtek Inverter UPS might be working on battery due to a dead wall socket or loose line AC input connections. Check the glass fuse at the rear. If it's blown, replace it with a 10Amp fuse. If the fuse continues to blow, contact an authorised service engineer.

Summary

THE PRODUCT

SALIENT FEATURES

Lists key technological advantages and design benefits for better performance and reliability.

FRONT PANEL - LCM-GRAPHIC LCD DISPLAY MODELS

LED Indications

Details the meaning of various LEDs on the front panel for status and fault indication.

FRONT PANEL - LED MODELS

LED Indications

Explains the function of LEDs on the front panel for status, battery, and fault indicators.

BACK PANEL

BACK PANEL

TROUBLE SHOOTING

Main Supply Issues

Addresses problems related to normal supply, fuse blown, and no output from the UPS.

Frequent Backup Trips

Explains causes and solutions for the UPS tripping frequently during backup mode.

No Power During UPS Mode

Covers issues like overload and the steps to reset the inverter for power restoration.

Low Battery Condition

Details troubleshooting for low battery issues, including charging and checking connections.

Short Circuit Faults

Provides guidance on identifying and resolving short circuit problems affecting the UPS.

Backup Time Issues

Addresses problems with the UPS not providing the expected backup duration.

UPS Not Operating

Outlines checks for battery, mains connections, internal faults, and fuse for non-operation.

BYPASSING THE UPS

TECHNICAL SPECIFICATIONS

SERVICING

WARRANTY

POST WARRANTY ANNUAL MAINTENANCE CONTRACT

Information on optional annual maintenance contracts for continued product support.

SAFETY INSTRUCTIONS

IMPORTANT PROCEDURES

GOING ON VACATIONS

Microtek SineWave UPS EB Specifications

General IconGeneral
Output WaveformSine Wave
ModelSineWave UPS EB
Input Voltage220/230/240VAC
Output Voltage220/230/240VAC
Input Voltage Range170-280VAC
Frequency50/60Hz ± 1Hz
Battery TypeLead-acid maintenance-free
Battery Voltage12VDC
No. of Batteries1 (600VA - 1200VA), 2 (1500VA - 2000VA)
Battery Charging CurrentStandard: 1A, Optional: 4A/8A
Efficiency>75%
Transfer Time2-6ms typical
ProtectionOverload, discharge, and overcharge protection
Communication InterfaceOptional: USB/RS232
Operating Temperature0-40°C
Operating Humidity0-90% relative humidity, non-condensing