P.61
7. Drum non-rotating malfunction maintenance
Change the control panel
N
The drum is blocked
Drum non-rotating
Y
Whether the door
is closed correctly
Close the door
Whether the door
lock is well
Y
N
Change the door lock
N
Y
Y
Y
Whether the motor
is well
Whether the
connection of main
and auxiliary wiring
harness is well
N
Reliable connection
Y
Whether the inlet
is correct
N
Waiting inlet or inspect
overtime water inlet
malfunction
Whether the
switch is well
pressure
Y
Y
N
Replace it
N
Replace it
Detach strap,
whether the drum
is rotating flexibly