10Use Pipe cutter cut off the condenser tube, then
Shear off capillary by the capillary tube scissors.
11Replace the compressor and welding the compressor
pipeline.-Welding the process pipeline.-Welding the
low-pressure muffler.-Welding the high-pressure
exhaust pipe.
12Replace the filter, Cu-Fe tubes welding used Ag
welding rod, Cu-Cu tubes welding used Cu welding
rod.
13Vacuum system,The degree of vacuum below 6Pa.
14Perfusion refrigerant.