10. Troubleshooting
10.1 Indoor unit error code explanation:
PREMIER series +OASIS series+9A series +R series +12F series +Aurora series:
Display
Operation lamp flash times
Timer lamp
Failure
E0
1
X
Indoor EEPROM malfunction
E1
2
X
Indoor / outdoor units communication error
E3
4
X
Indoor fan speed has been out of control
E4
5
X
Open or short circuit of T1 temperature sensor
E5
6
X
Open or short circuit of T2 temperature sensor
F1
2
O
Open or short circuit of T4 temperature sensor
F2
3
O
Open or short circuit of T3 temperature sensor
F3
4
O
Open or short circuit of T5 temperature sensor
F4
5
O
Outdoor EEPROM parameter error
F5
6
O
Outdoor fan speed out of control
F6
7
O
Open or short circuit of T2B temperature sensor
P0
1
IPM module protection
P1
2
Voltage protection
P4
5
Inverter compressor drive protection
P5
6
Mode conflict
P6
7
Low pressure protection(Just matching with
M4OA-36HFN1-Q,M4OD-28HFN1-Q,M5OC-36HF
N1-Q, M5OD-42HFN1-Q)
O light X off flash
Light Commercial series(Except Console)
NO.
MALFUNCTION
RUN
Timer
DEF
Alarm
DISPLAY
DIGITAL TUBE
1
Open or short circuit of T1 temperature sensor
X
X
X
E0
2
Open or short circuit of T2 temperature sensor
X
X
X
E1
3
Indoor / outdoor units communication error
X
X
X
E2
4
Full-water malfunction
X
X
X
E3
5
Indoor EEPROM malfunction
X
X
E4
6
IPM module protection
X
X
O
E5
7
Open or short circuit of T3 or T4 temperature sensor or
Outdoor EEPROM malfunction
O
X
X
E6
8
Outdoor fan speed has been out of control
O
X
E7
9
Indoor fan speed has been out of control
O
O
X
F5
10
Voltage protection
O
X
O
P0
11
Outdoor unit over-current protection
X
P2
12
Inverter compressor drive protection
X
X
P4
13
Mode conflict
X
O
O
P5
Flash(at 2.5Hz) Flash(at 0.5Hz) O light Xoff
Note: Digital display is only available for A5 duct type.