EasyManuals Logo

Midea M2OG-14HFN8-Q Service Manual

Midea M2OG-14HFN8-Q
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
10.3.3.4 Voltage protection(ODU E5)
Outdoor unit low AC voltage protection(PC10)
Outdoor unit main control board DC bus high voltage protection(PC11)
Outdoor unit main control board DC bus high voltage protection /341 MCE error(PC12)
Voltage protection
Check the voltage of
outdoor unit power supply,
whether the voltage
between L(L1) and N (L2) is
about 220~240VAC
Check the power supply
Check whether the voltage
of IPM board P and N is
normal? DC277-356V for
18-27KBtu/h; DC277-410V
for 36-42KBtu/h
Replace bridge rectifiers,
and then check whether the
system can run normally
Replace IPM board, and
then check whether the
system can run normally
Replace outdoor main board
Yes
No
No
No
No
Yes
Trouble is solved
Yes
Yes

Other manuals for Midea M2OG-14HFN8-Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea M2OG-14HFN8-Q and is the answer not in the manual?

Midea M2OG-14HFN8-Q Specifications

General IconGeneral
BrandMidea
ModelM2OG-14HFN8-Q
CategoryAir Conditioner
LanguageEnglish

Related product manuals